User's Manual Part 3

Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
129
6
RS 485/232 Communication Protocol
6.5.3. Parameters Table:
The following table relates to the Read and Write Parameters
Commands:
# Parameter
Name
Parameter
Code
Parameter
Syntax
Read/Write
Access *
Default
value
[unit]
Unit Parameter
length
1
Version of
MCU_firmwar
e
01 h MVER R 2 Byte
2
Version of
S1_firmware
80 h SVER1 R 2 Byte
3
Version of
S2_firmware
40 h SVER2 R 2 Byte
4
RSSI ch1 87 h RSSI1 R 1 Byte
5
RSSI ch2 47 h RSSI2 R 1 Byte
6
Reader ID 02 h RID R / 1 00000000 4 Byte
7
ADI ch1 81 h ADI1 R/W 00000000 4 Byte
8
ADI ch2 41 h ADI2 R/W 00000000 4 Byte
9
OrgID* 04 h OrgID R / 2 0000 2 Byte
10
Department
ch1
82 h DEP1 R/W 1 Byte
11
Department
ch2
42 h DEP2 R/W 1 Byte
12
Thw ch1 85 h Thw1 R/W 997 3.072ms 2 Byte
13
Thw ch2 45 h Thw2 R/W 997 3.072ms 2 Byte
14
Reader
Address
03 h RADD R/W 0000 2 Byte
15
Transmitter
Power ch1
88 h TRPOR1 R/W 65 1 Byte
16
Transmitter
Power ch2
48 h TRPOR2 R/W 65 1 Byte
17
System ch1 83 h SYS1 R/W ** 1 Byte
18
System ch2 43 h SYS2 R/W ** 1 Byte
19
Mode ch1 84 h MODE1 R/W 00 1 Byte
20
Mode ch2 44 h MODE2 R/W 00 1 Byte
21
Hard wakeup
ch1
86 h T
HP1
R/W 3256 3.072ms 2 Byte
22
Hard wakeup
ch2
46 h T
HP1
R/W 3256 3.072ms 2 Byte
* /1 or /2 defines the LOCK level.