All data transfers to the device through the Data Register are 16 bits with the exception of the ECC bytes,
which are 8 bits.
13.3 Non-Data Commands
These commands are as follows:
y Check Power Mode
y Enable/Disable Delayed Write
y Execute Device Diagnostic
y Flush Cache
y Format Unit
y Idle
y Idle Immediate
y Initialize Device Parameters
y Read Native Max ADDRESS
y Read Verify Sectors
y Recalibrate
y Seek
y Sense condition
y Set Features
y Set Max ADDRESS
y Set Multiple Mode
y Standby
y Standby Immediate
Execution of these commands involves no data transfer.
The following are the steps in the execution process:
1. The host writes any required parameters to the Features, Sector Count, Sector Number, Cylinder,
and Device/Head Registers.
2. The host writes the command code to the Command Register.
3. The device sets BSY=1.
4. When the device has finished processing the command, it sets BSY=0, and interrupts the host.
5. In response to the interrupt, the host reads the Status Register.
6. The device clears the interrupt in response to the Status Register being read.
Hard disk drive specification for DSCM-11000/-10512/-10340