Datasheet
13.5.20 Sense Condition (F0h : vendor specific)
...See Below...Status00001111Command
----D---Device/Head----D1-1Device/Head
--------Cylinder High--------Cylinder High
--------Cylinder Low--------Cylinder Low
--------Sector Number--------Sector Number
VVVVVVVVSector Count--------Sector Count
...See Below...Error10000000Feature
--------Data--------Data
01234567Register01234567Register
Command Block Input RegistersCommand Block Output Registers
V0--V0VV00V00000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCBBK
0123456701234567
Status RegisterError Register
Figure 96. Sense Condition Command (F0h)
The Sense Condition command is used to sense temperature in a device.
This command is executable without spinning up even if a device is started with No Spin Up option.
Temperature is higher than 107°CFFh
Temperature is (Value / 2 – 20)°C01h-FEh
Temperature is equal to or lower than –20°C00h
DescriptionValue
The Sector Count register contains result value.Sector Count
Input Parameters From The Device
The Feature register must be set to 01h. All other value are rejected with
setting ABORT bit in status register.
Feature
Output Parameters To The Device
Hard disk drive specification for DSCM-11000/-10512/-10340