Http://www.hexin-technology.
Http://www.hexin-technology.com/ 1. Product Introduction Product Description Technical Specification External Connector Installation 2. Operating Guide HXSP-2108E Configuration Communication Test Stand-alone Test Running Test 3.
Http://www.hexin-technology.com/ 1. Product Introduction 1.1. Product Description The HXSP-2108E Serial to TCP/IP Serial Device Server is a bidirectional switching and transmission device from serial port to Ethernet TCP/IP protocol. It changes the traditional serial communication to Ethernet communication. It realized speed networking for serial device.
Http://www.hexin-technology.com/ 1.4. Installation The HXSP-2108E Serial to TCP/IP Serial Device Server use WINDOWS application program ezConfig to set parameter through network. Therefore, user need install the network card in computer and set network environment. If it needs connect many HXSP-2108E equipments, user also need the network switchboard or HUB 1) Install the network card and set IP address and subnet mask.
Http://www.hexin-technology.com/ 2. Operating Guide 2.1. HXSP-2108E Disposition HXSP-2108E adopt the transparent transmission means to deal with data, namely any data the serial port receives is retransmitted to the network. The user may use any communication protocol to realize network communication without changing the original procedure. Then HXSP-2108E adopts WINDOWS application procedure-ezConfig and disposes parameter through network.
Http://www.hexin-technology.com/ click [Search]. Physical address is shown in the physical address tabulation frame after the software found the converter as below: 2.Choose the physical address and the other parts would be efficient. Now read and set the converter parameter. Which can be reread to relative switch parameter is confirmed to be OK. 3. You can test its reach capability after setting is completed using PING test in DOS windows.
Http://www.hexin-technology.com/ 2.2. Communication Test 2.2.1. Stand-alone test After the disposition completed, we need to carry on simple test to confirm the accuracy of the setting and HXSP-2108E. The single plane test adopts the means of receiving and dispatching of the data packets between the super terminal (the RS232 serial port) and WINDOWS application procedure e1Test (Ethernet TCP/IP) to confirm. The single plane test step is as follows: 1) Correct install and connect HXSP-2108E (RF.1.
Http://www.hexin-technology.com/ [PC IP address] Choose PC IP address. The procedure automatically searches all IP address of the computer and chooses the most possible one. If wrong, you can choose through the frame. [Local port] The port is to receive a TCP/UDP package. [Communication protocol] Choose UDP protocol. Better not to choose TCP protocol [Interception] Intercept the TCP connection of HXSP-2108E. [Module IP Address] To show opposite party’s IP Address.
Http://www.hexin-technology.com/ appear in the e1Test receiving window (whether the super terminal can reshow tbe transmission character is decided by the corresponding set of converter), otherwise the e1Test transmission information can be seen in the super terminal window. 2.2.2. running test The design goal of HXSP-2108E is to realize network communication by serial port with the extremely low cost.