Product Manual
19/28
Hexagon Mining
Baarerstrasse 133
6300 Zug, Switzerland
www.hexagonmining.com
If a PA installation presents connectivity issues check the cabling for the following best practices being
applied:
The CAN-bus cabling resembles a simple daisy chain.
The M12-4 terminator pieces are installed at both ends of the CAN-bus.
The CAN-bus cabling has no branches other than individual vehicle Anchor units and one CAS
unit attached to it. The entire system must describe a bus.
The CAN-bus should not close on itself, nor should it create any other type of loop.
Each Vehicle Anchor on the vehicle has its own unique ID (0-6)
Check the configuration parameters of the PA on the CAS.
Check that the system has not been damaged by excessive supply volpedestrian tage or that
the fuses of the power supply were blown.
If the error persists after having checked the installation for the application of best practices and
assessing the system for faulty equipment, please contact your Hexagon Mining support responsible.
5.2. PEDESTRIAN TAG
5.2.1. Errors
If the PEDESTRIAN TAG is on an error state a combination of LEDs will indicates the possible causes
as shown in the table below:
Error Type Possible Causes User Interface
PEDESTRIAN TAG
not communicating
Battery is flat.
No Firmware Firmware is not correct or have not
been uploaded.