Battery medium The right and left LEDs will glow in
AMBER colour for 2 seconds.
Battery low The right and left LEDs will glow in
RED colour for 2 seconds
5. System Status
5.1. CAS+PA
5.1.1. Errors
If the CAS Main Unit encounters an error of the Personal Alert System (PA) a combination of LEDs will
indicate its findings on the display. If an Error is displayed check the cabling, the connections and the
sensor units for proper operation.
Error Type Possible Causes User Interface
PA Error
Vehicle Anchor Malfunction
PA Wiring fault
Vehicle Vehicle Anchors
disconnected
Wrong Vehicle Anchor
configuration
CAN-Bus Error
Communications Error
(renders PA System
inoperable)
PA Faults as above