7 CAS 10 Visitor Unit
CAS 10 Visitor Unit suits temporary CAS 10 installations on vehicles for visitors of a mine or
short-term contractors to ensure all vehicles are protected by CAS.
CAS 10 Visitor units contain QC1000 Smart Antenna with a magnetic mount and QD1400 Display
5 with RAM mounts and suction cups for quick installations. Part of the set is the QX1300 CAS 10
Battery pack as an independent power source. The battery pack can be connected to the
cigarette lighter of the vehicle for prolonged lifetime.
In between use, the battery pack must be charged using the provided QM251 charger (110/230V)
7.1 QX1300 CAS 10 Battery Pack
7.2 Top View
Indication
Mode
Meaning
Orange LED
Blinking at 0.5 Hz
Battery being charged
Continuous
Battery is fully charged
Blinking at 2.5 Hz
Battery Error
None
No battery connected/detected or input voltage
too low
Orange LED
Continuous
Power Supply is present
Indicates Battery
charge status
Indicates presence
of power supply