Installation Manual

Internal Documents Do not Distribute
18 Commercial in Confidence © Hexagon AB
Pin
Name
Description
17
CAN2-L
High level CAN bus input/output line
dedicated CAN for VIS
18
CAN1-H
High level CAN bus input/output line
for the communication with Radars / PA …
the same signal as on Pin 12
19
CAN1-L
Low level CAN bus input/output line
for the communication with Radars / PA …
the same signal as on Pin 2
5.11 Face plate/Label Description
A label is placed at the lower side of the QC1000 indicating Model, Article Number, Manufacturer
and compliance statements. Label is white print on black background.
5.12 User Interface LED bar
At the front of the Smart Antenna, there is a light bar backed with
high-brightness LEDs. LED bar provides indications on system
status. The LED bar provides system status during installation as
well as during operations.
Condition
LED color
LED intensity
LED timing
Comment
Bootloader started
RED
Max intensity
Constant on
For errors like no valid
firmware found.
Bootloader error
RED
Max intensity
Double blink
This is when there is a
permanent error
during start-up, such
as an unsupported
CPU detected.
QC1000 running - OK
GREEN
Based on
ambient light
Short blink
every 5s
Shown in normal
operation if no error
is present.