Datasheet

3
HP V1410 Switch Series
Specifications
HP V1410-8G Switch (J9559A) HP V1410-16G Switch (J9560A) HP V1410-24G Switch (J9561A)
Ports
8 autosensing 10/100/1000 ports (IEEE 802.3
Type 10BASE-T, IEEE 802.3u Type 100BASE-TX,
IEEE 802.3ab Type 1000BASE-T); Media Type:
Auto-MDIX; Duplex: 10BASE-T/100BASE-TX: half
or full; 1000BASE-T: full only
16 RJ-45 autosensing 10/100/1000 ports (IEEE
802.3 Type 10BASE-T, IEEE 802.3u Type
100BASE-TX, IEEE 802.3ab Type 1000BASE-T);
Media Type: Auto-MDIX; Duplex:
10BASE-T/100BASE-TX: half or full; 1000BASE-T:
full only
22 autosensing 10/100/1000 ports (IEEE 802.3
Type 10BASE-T, IEEE 802.3u Type 100BASE-TX,
IEEE 802.3ab Type 1000BASE-T); Media Type:
Auto-MDIX; Duplex: 10BASE-T/100BASE-TX: half
or full; 1000BASE-T: full only
2 dual-personality ports; each port can be used as
either an RJ-45 10/100/1000 port (IEEE 802.3
Type 10Base-T; IEEE 802.3u Type 100Base-TX;
IEEE 802.3ab 1000Base-T Gigabit Ethernet) or
an open mini-GBIC slot (for use with mini-GBIC
transceivers)
Physical characteristics
Dimensions
3.8(d) x 6.14(w) x 0.96(h) in. (9.65 x 15.6 x
2.45 cm) (.5U height)
4.41(d) x 8.21(w) x 1.73(h) in. (11.2 x 20.85 x
4.4 cm) (1U height)
6.65(d) x 13.23(w) x 1.73(h) in. (16.9 x 33.6 x
4.4 cm) (1U height)
Weight
.74 lb. (0.34 kg) 1.43 lb. (0.65 kg) 2.98 lb. (1.35 kg)
Memory and processor
4 Kb EEPROM capacity; packet buffer size: 192
KB
512 KB flash; packet buffer size: 512 KB 512 KB flash; packet buffer size: 512 KB
Mounting
Wall, desktop, and under-table mounting Mounts in an EIA-standard 19 in. telco rack
(hardware included); wall, desktop, and
under-table mounting
Mounts in an EIA-standard 19 in. telco rack
(hardware included); wall, desktop, and
under-table mounting
Performance
100 Mb Latency
< 3.6 µs (LIFO 64-byte packets) < 8.0 µs (LIFO 64-byte packets) < 8.0 µs (LIFO 64-byte packets)
1000 Mb Latency
< 1.2 µs (LIFO 64-byte packets) < 3.6 µs (LIFO 64-byte packets) < 3.6 µs (LIFO 64-byte packets)
Throughput
up to 11.9 million pps (64-byte packets) up to 23.8 million pps (64-byte packets) up to 35.7 million pps (64-byte packets)
Switching capacity
16 Gbps 32 Gbps 48 Gbps
MAC address table size
4096 entries 8000 entries 8000 entries
Environment
Operating temperature
32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C)
Operating relative humidity
15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
15% to 90% @ 149°F (65°C), noncondensing 15% to 90% @ 149°F (65°C), noncondensing 15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft. (3 km) up to 10,000 ft. (3 km) up to 10,000 ft. (3 km)
Acoustic
Power: 0 dB No fan Power: 0 dB No fan Power: 0 dB No fan
Electrical characteristics
Maximum heat dissipation
41 BTU/hr (43.26 kJ/hr) 44 BTU/hr (46.42 kJ/hr) 75 BTU/hr (79.13 kJ/hr)
Voltage
100-240 VAC 100-240 VAC 100-127/200-240 VAC
Current
1.0 A 1.1 A 0.3/0.2 A
Maximum power rating
12 W 13 W 22 W
Frequency
50/60 Hz 50/60 Hz 50/60 Hz
Notes
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all
modules populated.
The exact input voltage and frequency rating are
determined by the specific power adapter part
number ordered. Please select the correct power
adapter country option.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all
modules populated.
The exact input voltage and frequency rating are
determined by the specific power adapter part
number ordered. Please select the correct power
adapter country option.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all
modules populated.
Safety
CSA 22.2 No. 60950; EN 60950/IEC 60950;
UL 60950-1
CSA 22.2 No. 60950; UL 60950-1; IEC
60950-1; EN 60950-1
CSA 22.2 No. 60950; UL 60950-1; IEC
60950-1; EN 60950-1
Emissions
FCC Rules Part 15, Subpart B Class A FCC Rules Part 15, Subpart B Class A FCC Rules Part 15, Subpart B Class A
Immunity
Generic
EN 55022 CISPR 22 EN 55022 CISPR 22 EN 55022 CISPR 22
EN
EN 55024, CISPR 24 EN 55024, CISPR 24 EN 55024, CISPR 24
ESD
IEC 61000-4-2 IEC 61000-4-2 IEC 61000-4-2
Radiated
IEC 61000-4-3 IEC 61000-4-3 IEC 61000-4-3
EFT/Burst
IEC 61000-4-4 IEC 61000-4-4 IEC 61000-4-4
Surge
IEC 61000-4-5 IEC 61000-4-5 IEC 61000-4-5
Conducted
IEC 61000-4-6 IEC 61000-4-6 IEC 61000-4-6
Power frequency magnetic field
IEC 61000-4-8 IEC 61000-4-8 IEC 61000-4-8
Voltage dips and interruptions
IEC 61000-4-11 IEC 61000-4-11 IEC 61000-4-11