Specifications
• Cartridge in Transport — the slot number where the tape currently in the robot originated. None
if there is not a tape in the robotic.
• Odometer — the total number of moves the device has performed since its manufacture.
• Total Power On Time — the number of days, hours, and minutes that the device has been powered
on since its manufacture.
• Robotic Status — the current status of the robotics and a description of the operation the robot is
currently performing.
• Internal Temperature — the internal temperature reported by the device.
• Media Removal — Prevented, if the backup software is preventing media removal from the device.
When media removal is prevented, the mailslot and magazine functionality is disabled.
• Left Magazine — Present, if the device senses the presence of the left magazine.
• Right Magazine — Present, if the device senses the presence of the right magazine.
Viewing dynamic drive information
The Status: Drive page (parallel SCSI), Figure 32, and Status: Drive page (SAS) provide detailed
information about the tape drive in the Autoloader. When you click Refresh, the status is updated
immediately.
Figure 31 Status: Drive page (parallel SCSI)
.
Operating the Tape Autoloader58