Datasheet

NOTE:
When populating the second optional riser slot, the second processor must be installed.
NOTE:
All slots support up to 150w PCIe cards, but an additional Power Cord Option is required (PN
669777-B21). See Option Section below for offering.
PCIe Riser
(Optional 3-slot)
Expansion
Slots #
Technology
Bus
Width
**
Connector
Width
Bus Number*
Form Factor
Notes
4
PCIe 3.0
X16 X16
16
Full Length,
Full Height
Slot
Proc 2
5
PCIe 3.0
X8 X8
20
Half Length,
Full Height
Slot
Proc 2
6
PCIe 3.0
X4 X8
23
Half Length,
Full Height
Slot
Proc 2
* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment
number
** Indicates the number of physical electrical lanes running to the connector.
NOTE:
When populating the second optional riser slot, the second processor must be installed.
NOTE:
All slots support up to 150w PCIe cards, but an additional Power Cord Option is required (669777-
B21). See Option Section below for offering
Storage Controller
NOTE:
HP StoreEasy 3840 Gateway Storage products include a storage controller designed for internal
drives housing the O/S mirror only; an HBA is required to address external SAN or array storage.
Controller(s)
HP Smart Array P420i/1GB with FBWC
RAID
0/1/1+0/5/5+0
Storage
Hard Drives
3840
Internal
Eight 2.5" (Small Form Factor) hot-plug bays
2 x 300GB 6G SAS 10K SFF HDDs for O/S mirror
External
Designed for attach to Fibre Channel (HBA required), SAS (HBA required), or
iSCSI (Microsoft iSCSI initiator included) arrays
Power Supply
2 x 750 Watts G
Power Cords
NOTE:
The HP StoreEasy 3840 Gateway Storage products are primarily connected to PDU's in data center
racks so they now ship standard with only a PDU 6-foot C-14 to C13 power cord (142258-001). If a user
wishes to power a system using a110V receptacle see Power Cord option section for more options.
System Fans
(4) (N+1 redundancy standard)
QuickSpecs
HP StoreEasy 3000 Gateway Storage
Standard Features
DA - 14435 North America — Version 8 — April 18, 2014
Page 7