Installation Instructions
HESTAN RESIDENTIAL INSTALLATION MANUAL
6
hestanoutdoor.com
PREPARING THE SPACE
If  the  unit  is  to  be  installed  under 
a  countertop,  it  is  recommended 
that the countertop be supported by a structure other 
than the unit itself to prevent damage to the unit. 
unit  is  level  with  the  surrounding 
cardboard,  or  some  other  suitable  material  before 
moving  the  unit  into  place.  Failure  to  do  this  may 
1).  Make  sure  the  space  opening  is  correctly  sized  for 
requirements: 
CAUTION
CAUTION
 24” Hestan Models
Height Depth Width
34-3/8” minimum,
35-1/2” maximum
24” 24”
installations to assure a full 90° opening. Allow 25” clearance 
in front of unit for full door swing and shelf/drawer pull out for 
all units.
2). Check that the following are level and square:
•  Front and interior opening
• 
•  Countertop bottom front edge
To prevent possible damage to the 
countertop,  do  not  place  heavy 
objects on countertop directly over unit.
INS
TALLING THE UNIT
1).  Plug  the  unit  into  the  15  amp  grounded  electrical 
outlet located within the installation opening. With power 
applied  to  the  unit,  check  that  the  lighting  and  cooling 
outlet at the circuit breaker.
2). With all surfaces in the installation opening square and 
level, refer to Figure 2 on page 7 and perform the following 
steps to level the unit:
• 
the bottom of the front edge of the countertop.
• 
the rear corners.
•  Adjust  the  unit  legs  so  these  two  measurements  are 
equal.  Using  an  adjustable  wrench  or  pliers,  turn  legs 
clockwise to lower the unit or counterclockwise to raise it.  
NOTE: Legs should not extend more than 3/4” from the bottom 
of the unit. 
3). Slide the unit into position in the opening. Make sure 
the rear leveling legs slide under the ant-tip brackets. Push 
the unit into the opening until the bottom front edge of 
rear legs are tight against the anti-tip brackets.
with  the  surrounding  cabinetry.  Adjust  the  front  legs  to 
support  the  countertop  at  the  shimmed  height.  Using 
an adjustable wrench or pliers, turn the legs clockwise to 
lower the unit or counterclockwise to raise it. Countertop 
should be resting on top of the unit.
NOTE: Countertop should be resting evenly on entire top of the 
unit. Shim if necessary to prevent damage to the countertop.
CAUTION
Make sure the floor under the
finished floor. Protect a finished floor with plywood
result in damage to the floor.
the unit. See chart below for finished rough opening
Installation opening and floor surface
NOTE: The floor under the unit must be at the same level as 
surrounding finished floor.
functions operate properly. Turn off the power to the wall
At the front of the opening, measure from the floor to
Measure from the floor surface to the top of the unit at
the unit is flush with the surrounding cabinetry, or until the
4). Shim the front of the unit so the front face is flush
open a minimum of 90°. Use a minimum 3” filler in corner
NOTE: For a cabinet door to open properly, the door must