Installation and Instruction Manual

15
NOTICE
• Protect the oor when moving the ice machine to prevent damage to the oor.
• If using the optional drain pump (AGDP), test its operation every time the ice
machine is cleaned and sanitized. See "IV.E. Optional Drain Pump AGDP" for
details. If the optional drain pump is not operating properly, water could back up
and overow, leading to costly water damage.
To help ensure that the storage bin drain remains clear, follow the instructions
in "IV.C.Storage Bin Drain" once every 3 months or as often as necessary for
conditions. If the storage bin drain becomes clogged, water could build up in the
bin and overow, leading to costly water damage.
• If water collects in the bin and will not drain, turn off the ice machine and close the
water supply line shut-off valve. Call for service.
• Do not leave the ice machine on during extended periods of non-use, extended
absences, or in sub-freezing temperatures. To properly prepare the ice machine
for these occasions, follow the instructions in "V. Preparing the Ice machine for
Periods of Non-Use."
• Keep ventilation openings, in the appliance enclosure or in the built-in structure,
clear of obstruction.
• Do not place objects on top of the ice machine.
The storage bin is for ice use only. Do not store anything else in the storage bin.
B. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the ice machine is turned off, wait for at least 3 minutes before restarting the ice
machine to prevent damage to the compressor.
At startup, conrm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve.
2) Make sure the control switch is in the "OFF" position. Plug the unit into the electrical
outlet. WARNING! To reduce the risk of electric shock, do not touch the control
switch or plug with damp hands. If you have to slide the unit back for a built-in
installation, make sure you do not damage or pinch the water supply line, drain line, or
power cord.
3) If required by sanitation code in your area, seal the perimeter where the machine
touches the oor with approved caulk compound in a smooth and easily cleanable
manner.