Installation and Instruction Manual

EN
©2021 Hestan Commercial Corporation
9
INSTALLATION INSTRUCTIONS
(continued)
1. Make sure the space opening is correctly sized for the unit. See typical appliance dimensions on
page 7 and the chart below for finished rough opening requirements:
HEIGHT WIDTH DEPTH
34” [86.4 cm] min.
34-1/2” [87.6 cm] max.
15” [38.1 cm] 24” [61 cm]
2. Check that the following are level and square:
Front and interior opening
Installation opening and floor surface
Countertop bottom front edge
NOTE: The floor under the unit must be at the same level as surrounding finished floor.
To prevent possible damage to the countertop, do not place heavy objects on countertop directly
over unit.
Do not let the weight of the countertop rest on the ice machine.
Do not install the ice machine in a corner where the door will interfere with other equipment or
where the ice machine cannot be pulled out for service.
The louvered sections at the front and rear of the unit must not be covered or obstructed.
Obstructions could prevent proper air circulation, which may damage the unit.
Min. 34"
(864 mm)
Min. 15"
(381 mm)
Between Two Cabinets Between a Cabinet and
the End of a Counter
Support: Do not
let the weight
of the counter
rest on the ice
machine
Min. 23"
(584 mm)
Oven
Ice machine
Between a Cabinet and
a Wall or Tall Cabinet
In a Corner
Secure: Do not
let the weight
of the counter
rest on the ice
machine
Min. 15"
(381 mm)
Min. 34"
(864 mm)