Installation and Instruction Manual

EN
©2021 Hestan Commercial Corporation
17
MAINTENANCE
(continued)
9. Soak all of the removed parts and the scoop in the sanitizing solution for 10 minutes. If the spray
assembly nozzles are clogged, clean them with a wire or a suitable brush.
10. Rinse the parts thoroughly with clean water.
11. Refit the 2 caps in their correct positions. Make sure the reducing pipe is in place in the center.
See Fig. 42.
12. Slide in the spray assembly along the rails on the left and right brackets. See Fig. 43. Connect the
discharge tube securely to the spray assembly; a loose fitting may cause a water leak.
Reducing Pipe
Rail
Rail
Fig. 42 Fig. 43
Right BracketLeft Bracket
Caps
Discharge Tube
13. Position and lock the ice chute onto the front and rear frame pipes by pushing the ice chute
down until it clicks onto both frame pipes. See Fig. 44.
14. Slide in the water tank along the rails at the bottom of the left and right brackets until it locks
into place. See Fig. 45.
15. Reconnect the suction tube.
16. Hook each separator onto the rail, then pull it hard towards you until it locks into place. See Fig.
46.
17. Replace the slope in its correct position. See Fig. 47.
Right Bracket
Rail
Rail
Fig. 44
Fig. 45
Left Bracket
Ice Chute
Front Frame
Pipe
Rear Frame
Pipe
Water Tank
Fig. 46
Fig. 47
Separator
Rail
Slope