Installation and Instruction Manual
EN
©2021 Hestan Commercial Corporation
16
MAINTENANCE
(continued)
SANITIZING PROCEDURESANITIZING PROCEDURE
1. Make sure the control switch is in the “OFF” position and the storage bin is empty.
2. Remove the slope from the storage bin by carefully bending it in the center and releasing it from
the 2 slope shafts. See Fig. 36.
3. Remove each separator by lifting it to the horizontal position and pushing it hard inward. See
Fig. 37.
Separator
Slope
Fig. 36
Fig. 37
Slope Shafts
4. Disconnect the suction tube. Allow the water tank to drain.
5. Spread out the tabs to unlock the water tank, then slide it out. See Fig. 38.
6. Lift off the ice chute from the front frame pipe and then from the rear frame pipe. See Fig. 39.
7. Disconnect the discharge tube from the spray assembly, then slide out the spray assembly. See
Fig. 40.
8. Remove the two caps. See Fig. 41.
Ice Chute
Front Frame Pipe
Tab Tab
Fig. 38 Fig. 39
Rear Frame Pipe
Water Tank
Discharge Tube
Spray Assembly
Fig. 40 Fig. 41
Caps