Quick Start Guide

©2016 Hestan Commercial Corporation
5
EN
TESTING & ADJUSTMENT
(continued)
TO TEST
Make sure all control valves are in the “OFF” position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
Check all connections from the supply line, or LP cylinder up to and including the manifold pipe
assembly.
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply,
tighten any leaking fittings, turn the gas supply back on, and recheck.
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased your
side burner.
Do not use the side burner until all connections have been checked and do not leak.
IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
LABEL
After conversion, the label below must be attached to the grill next to the existing rating label. The
qualified service technician will fill in the Gas Type, Manifold Pressure, and BTU Rates for each burner
type (per the chart above). The technician should sign and date the label as well.
BURNER / VALVE ADJUSTMENTS
Consult the GAS CONNECTIONS section of your Hestan outdoor appliance for full instructions on
burner adjustments, flame appearance, and valve adjustments. This step is very important to ensure
successful burner performance after conversion to the new fuel type, or changing orifices for high
altitude locations.