User's Manual

Setting4.2
Pandar40 supports both broadcast (default setting) and
unicast.
To use broadcast, please set Destination IP as
255.255.255.255. To use unicast, please set Destination IP as
the same as PC IP address.
Users can choose the dual return type from the last return, the
strongest return, and the dual return.
Users can choose the spinning rate from 600 rpm and 1200
rpm.
Users can choose the GPS sync angle. If set as 0, then the 0
degree angle is in sync with PPS.
Users can choose angle range less than 360° by specifying
start and end angles. There will be no laser firing or data
generated outside the specified angle range. If the start angle
and the end angle are the same, all lasers will only fire at this
particular angle.
Users can configure the rotation direction to clockwise or
anticlockwise. The coordinate system remain the same despite
the choice of rotation direction. Please refer to Figure 1.3 for
more details.
1)
2)
3)
4)
5)
6)
Figure 4.2 Setting Page of Web Control