Instruction Manual
3
Diagram 2: Faceplate Attachment
Installation Directions
Diagram 3: Determining Mortise Offset
To install the 700 series electric strike body to the
faceplate, install two #8-32 Body Mounting screws
as shown. Make sure bolts are tightened and secured.
Keeper position can be adjusted by loosening the #8-32
body mounting screws, and repositioning the strike body
as needed. Retighten body mounting screws after
adjustment is made
C
L
Strike
B
C
L
Mortise
Door Prep
4”
[101.60]
8”
[203.20]
*Best 45H & 47H are recommended for
use with the 742-75 only.
MORTISE LOCK B
CORBIN/RUSSWIN
SARGENT (8200)
YALE (8800)
ARROW, FALCON
0"
BEST 34H-37H 1/4"
SCHLAGE
3 /4"
YALE (8700) 7/8"
BEST 45H & 47H* 1/8"
3/16"