User Manual

7
SIGNAL MONITORING FACILITIES
As previously explained, the heart of the RAM System 5000 is its
microprocessor controlled, ladder type attenuator. This can be accessed in 2
ways:
Using the Red Level Knob: As in any traditional monitoring system.
Fully clockwise it performs at unity gain (maximum level) whilst
reducing it in 1dB steps up to 64. After this the unit turns Mute on.
Using the LEVEL PRESET OPTIONS: The RAM System 5000 has the
ability to store 2 different level presets, which override the Red Level
knob position. Pressing SHIFT + OUT5 (Level Preset) will ask for which
of the 2 presets wants to be stored (1 or 2). Confirmation is given by
pressing the corresponding key, OUT1 (Level Preset 1) or OUT2
(Level Preset2).Pressing SHIFT + OUT1 (Level Preset1) will make the
monitoring level that of the stored preset, same for preset 2.
ADDITIONAL MONITORING FEATURES
The RAM System has the usual MUTE, DIM, MONO and PHASE reverse
functions often found in this type of units with expanded flexibility as follows:
MUTE: Global Mute, equivalent to rotary knob all fully counter
clockwise.
MUTE L, C, R, RL, SUB and RR: Individual Mute functions per speaker.
Pressing SHIFT + any individual MUTE will function as a SOLO for that
given speaker.
DIM: Attenuates further 20 dB from the attenuation marked by
either the red knob or the level preset.
MONO: Accessible as SHIFT + MUTE, it outputs a mono signal to the
selected output.
PHASE: Accessible as SHIFT + DIM, left and right outputs are flipped
180 degrees.