MSDS
Use standard firefighting procedures and consider the hazards of other involved materials.
Specific methods
Flammable liquid and vapor.
General fire hazards
6. Accidental release measures
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Eliminate all
ignition sources (no smoking, flares, sparks, or flames in immediate area). Wear appropriate
protective equipment and clothing during clean-up. Avoid breathing mist or vapor. Do not touch
damaged containers or spilled material unless wearing appropriate protective clothing. Ventilate
closed spaces before entering them. Local authorities should be advised if significant spillages
cannot be contained. For personal protection, see section 8 of the SDS.
Personal precautions,
protective equipment and
emergency procedures
Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Take
precautionary measures against static discharge. Use only non-sparking tools. Keep combustibles
(wood, paper, oil, etc.) away from spilled material.
Large Spills: Stop the flow of material, if this is without risk. Use water spray to reduce vapors or
divert vapor cloud drift. Dike the spilled material, where this is possible. Cover with plastic sheet to
prevent spreading. Use a non-combustible material like vermiculite, sand or earth to soak up the
product and place into a container for later disposal. Prevent product from entering drains.
Following product recovery, flush area with water.
Small Spills: Absorb with earth, sand or other non-combustible material and transfer to containers
for later disposal. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS.
Methods and materials for
containment and cleaning up
Avoid release to the environment. Prevent further leakage or spillage if safe to do so. Avoid
discharge into drains, water courses or onto the ground. Inform appropriate managerial or
supervisory personnel of all environmental releases.
Environmental precautions
7. Handling and storage
Do not handle, store or open near an open flame, sources of heat or sources of ignition. Protect
material from direct sunlight. When using do not smoke. Explosion-proof general and local exhaust
ventilation. Take precautionary measures against static discharges. All equipment used when
handling the product must be grounded. Use non-sparking tools and explosion-proof equipment.
Do not get in eyes, on skin, or on clothing. Avoid breathing mist or vapor. Avoid prolonged
exposure. Wear appropriate personal protective equipment. Wash hands thoroughly after
handling. Avoid release to the environment. Observe good industrial hygiene practices.
Precautions for safe handling
Store locked up. Keep away from heat, sparks and open flame. Prevent electrostatic charge
build-up by using common bonding and grounding techniques. Store in a cool, dry place out of
direct sunlight. Store in original tightly closed container. Store in a well-ventilated place. Keep in an
area equipped with sprinklers. Store away from incompatible materials (see Section 10 of the
SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
Value
Type
Form
Components
PEL 240 mg/m32-Butoxyethanol (CAS
111-76-2)
50 ppm
PEL 5 mg/m3 Mist.Distillates (petroleum),
hydrotreated heavy
naphthenic (CAS
64742-52-5)
2000 mg/m3
500 ppm
US. ACGIH Threshold Limit Values
Value
Type
Form
Components
TWA 20 ppm2-Butoxyethanol (CAS
111-76-2)
Hercules Power Flow SDS US
925709 Version #: 01 Revision date: - Issue date: 23-April-2015
3 / 9