Technical Specifications
SUBMITTAL SHEET: Cryo-Tek™ Original
1
SPECIFICATIONS:
Cryo
-Tek™
Original
HCC Holdings, Inc.
4700 West 160th Phone: 800-321-9532
Cleveland, Ohio 44135 Website: www.Oatey.com
CRYO-TEK™ ORIGINAL Date: August 2017
Anti-Freeze for Heating and Cooling Systems
APPROVALS & LISTINGS
The virgin propylene glycol used in Cryo-Tek is “GRAS” (Generally Recognized As Safe) for incidental contact with food.
SPECIFIC USES
Use any Cryo-Tek Anti-Freeze in hydronic closed loop heating and cooling systems, solar heating systems, and general
plumbing systems that require freeze protection. Operating Temperature Range for Closed System: Up to 250°F
SPECIFIC APPLICATIONS*
Add any Cryo-Tek product to protect pipes from freezing and bursting. Also prevents freeze-ups in chiller systems,
recreational vehicles, seasonal homes, mobile homes, trailers, boats, sprinkler systems, and industrial use.
*For special applications which may not be covered on this or other Oatey literature, please contact Oatey Technical Services
Department by phone 1-800-321-9532, or fax 1-800-321-9535, or visit our technical database web-site at www.Oatey.com.
* Please check with equipment manufacturer of system to determine compatibility with this product.
**Minimum flow protection levels are estimated and are dependent on system and equipment.
A blend of virgin (not recycled) propylene glycol and high purity Triple Protection additives,
formulated for use in closed loop hydronic heating and cooling systems. Cryo-Tek can also be used in
radiant tube heating systems, most solar heating systems and geothermal loops. Hercules’ exclusive Triple
Protection formula stabilizes pH to prevent acid corrosion, chelates hard water minerals and inhibits the
formation of scale and sediment. These components work together to keep the system clean and operating
efficiently by eliminating system deposits, improving heat transfer and minimizing wear to moving parts and
seals. Cryo-Tek is compatible with PEX and elastomeric radiant tubing, commonly used materials for seals
and bushings and provides corrosion protection for cast iron, steel, copper, brass and solder. Cryo-Tek has
not been tested for use in systems containing CPVC plastic. Standard Cryo-Tek products should not be used
in systems containing aluminum. Cryo-Tek -100/AL is available for aluminum systems. Cryo-Tek should not be
used in systems with galvanized piping as the zinc coating will be dissolved. Cryo-Tek is a 94-98% efficient
heat transfer solution in most application dilutions. It has a lower freeze point and higher boiling point than
water and is non-flammable, odorless, non -toxic, nonirritating and compatible with Hercules boiler stop leaks
and heating system cleaner products.
Cryo-tek Original
Contains virgin (not recycled) propylene glycol with Triple Protection corrosion inhibitor, pre -mixed ready to
use formulation. Can be added directly into system undiluted or diluted as required. Certified Performance:
Freeze Protection Down to -22°F / -30°C, Pumpable Down to -27°F / -33°C, and Burst Protection Down to -
80°F / -62°C. Cryo-Tek Original can be further diluted with water for less severe conditions.(see Table II)
Test Kits and Accessories
Freeze protection levels and corrosion protection levels should be checked annually. Use Hercules
Refractometer (35290) and pH Meter (35272).Add additional Cryo-Tek product if freeze protection is
inadequate. Add Sludgehammer Universal Corrosion Inhibitor (35297) if pH is below 8.5. (see Maintenance)