Installation Guide

Oatey.com
INSTRUCTION GUIDE
HERCULES CRYO-TEK
TABLE I (NOTE: 1 US GALLON=3.785 LITERS)
Description
Pipe Diameter
Nominal Size
3/8" 1/2" 5/8" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3"
Standard
Steel Pipe
US Gallons of
Fluid per 100
ft. pipe
1.0 1.6 - 2.8 4.5 7. 8 10.6 17. 5 24.9 38.5
Type "L" US
Gallons of
US Gallons of
Fluid per 100
ft. pipe
0.76 1.22 1.81 2.52 4.30 6.55 9.27 16.12 24.86 35.48
3
Select Desired Temperature Coverage
Using Table II, determine the desired protection level and match it to the appropriate Cryo-Tek product
concentration.
Note: The percentages listed in the chart refer to the amount of Cryo-Tek solution and not the
actual percentage of glycol. (For example: 50% of the -100 is 27.5% glycol)
4
Determine Amount of Cryo-Tek Product Required in System
Determine the amount of Cryo-Tek product needed in the system by multiplying total system capacity in
gallons by the concentration factor of Cryo-Tek product (rst column in each chart above).
Total System Capacity (gal.)× Concentration Factor of Cryo Tek Product
(%)=Amount of Cryo Tek Product to be used (gal.)
TABLE II MIXING RATIO PROTECTIONS
% Concentration of
Cryo-Tek -100
Parts of Cryo-Tek -100 Parts of Water
Freeze Protection
Down to
Pumpable *
Down to
Burst Protection
Down to
100% undiluted - -70°F/-57°C -8F/-62°C -100°F/-73°C
75% 3 1 -2F/-30°C -33°F/-36°C -60°F/-5C
60% 3 2 0°F/-18°C -10°F/-23°C -40°F/-40°C
50% 1 1 +10°F /-12°C +5°F/-15°C -2F/-2C
*Pumpable down to protection levels are estimated and are dependent on system and equipment. Attempting to circulate uid below freeze point may overload
and/or cause pump failure