Owner's Instructions

If exposed to any of the Chemicals mentioned in the Hazards section please follow the
procedures below:
Eyes.
Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower
eyelid.
Seek medical attention.
Skin.
Remove contaminated clothing and rinse skin with plenty of water or shower for 15 minutes.
Seek medical attention.
Inhalation.
Vacate from site of exposure to fresh air immediately. Use oxygen if available.
Ingestion.
Give at least two glasses of milk or water. Induce vomiting unless patient is unconscious.
Seek medical attention.
Note:
Inhalation, skin contact and eye contact are possible if the battery is damaged.
Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous
membranes.
Overexposure can cause symptoms of non-broid lung injury and membrane irritation.
First Aid Measures
Data
Spare Parts
902928 Lithium-Ion Battery
903245 Charger UK (Hard Wired)
901607 11” TriTex Filter
909291 NVM - 1CH HepaFlo Dust bags x 3
907076 NVM - 1CH HepaFlo Dust bags x 5
907075 NVM - 1CH HepaFlo Dust bags x 10
Drum Size Operating Times Weight
(Ready to work)
Protection Class
6 L Hi = >20 mins
Lo = >30 mins
6.88 kg Class III
Sound Pressure Size
Hi = 64.5 dB (A)
Lo = 62.6 dB (A)
Uncertainty 0.5 dB
320 x 340 x 320 mm