Corp. Food Warmer User Manual
Model CW-216/CW-114
2-6. ELECTRIC CONNECTION The electrical power can be connected from the bottom or from
(Continued) the operator’s side. There is a 1-3/32 inch diameter hole from
either connection. Again, we recommend the bottom connection
as this will give a cleaner appearance to the unit. Please observe
the electrical connection information on the data plate located on
the side panel of the control end.
To avoid damage to unit, voltage potential of L
1
and L
2
to
ground cannot exceed 125 volts.
2-7. ELECTRIC DATA
TABLE Model Volts Phase Watts Amps
CW-114 230 3 3400 13.2
CW-114 230 1 3400 16.3
CW-114 208 3 3400 13.8
CW-114 208 1 3400 17.6
CW-216 230 3 4160 14.4
CW-216 230 1 4160 21.0
CW-216 208 3 4160 15.3
CW-216 208 1 4160 22.5
2-8. WATER SUPPLY The automatic water system has a 1/4 inch compression fitting for
CONNECTION copper tubing. Hot water would be preferred. We recommend
using the automatic water system as this will allow the unit to
maintain a more even water temperature and help ensure that the
unit never runs dry of water.
A straight-through bulkhead fitting is furnished with the unit for 1/4
inch copper tubing to protect the water line where it passes through
the sheet metal.
Reinstall the end panel.
203 2-5