User manual

26
7 Communication interface
8 Technical data
These operating instructions only contain the supplementary technical data for
the interfaces. Further technical data can be found in the operating instruc-
tions 2772083.
RS-232 interface
(Tico 774)
Also known as EIA-232, it is one of the stan-
dards for serial interfaces.
Socket on the counter: Micro Fit 3.0 from Molex, 3-pin
Data cable: Micro Fit 3.0 socket to 9-pin D-Sub connector
(S/UTP CAT-5 cable)
Cable length: max.15 m
Baud rate: 38.400 baud / Parity: even / 8 bit / Stop bits: 1
(factory setting, see section 4 for setting
options)
USB interface
(Tico 773)
The Universal Serial Bus (USB 2.0) is a serial
bus system for connecting external appliances
during operation.
Socket on the counter: for USB stick: Type A
for USB stick: Type Mini AB
Data cable: A connector to B-Mini connector, 5-pin
Cable length: max. 3 m
Use USB cables with noise filters to suppress
interference.
For a failure-free operation we recommend
our USB-cable No. 3 539 835
p1_tico_773_2773001_Betriebsanweisung_06062011_de_en.indb 26 02.02.2012 15:49:02