User manual

18
6 Configuring with the programming assistant
rESEt
E2
Error 2: Drive was removed during the configuration pro-
cess
The USB drive was removed during configuration. The process
is aborted. The counter must be restarted to reset any possible
errors in the configuration. This is shown by the message “rE-
SEt” on the display. Press any key on the counter to restart it.
In order to reconfigure the counter, remove the USB drive and
insert again.
rESEt
E3 XXX
Error 3: A configuration command has produced an error
message
A command error has occurred during configuration of the
counter, i.e., one of the commands in the configuration file re-
ported an error. The digits shown here as XXX (e.g., 014) refer to
the command error in the configuration file. It represents the
sequential number of the executed commands, not the row
number. Example: If error “14” is displayed, the error is con-
tained in the 14th command in the configuration file, irrespec-
tive of how many comments are noted.
USB
Abort
Configuration has been aborted
This message appears in the display if the configuration pro-
cess is not started within the specified time after finding the
configuration file, or if the process is manually aborted. The
display returns to standard view after a couple of seconds.
p1_tico_773_2773001_Betriebsanweisung_06062011_de_en.indb 18 02.02.2012 15:49:02