6 Configuring with the programming assistant
USB
noFILE
No file found
Neither a global nor single configuration file has been found.
The configuration process has been aborted. The display re-
turns to standard view after a couple of seconds.
USB
GLObAL
Global configuration file found
A global configuration file has been found. Press ā€œEā€ to con-
firm and start the configuration process. Press any other key to
abort the process. If no keys are pressed within 10 seconds, the
process is, again, automatically aborted.
USB
SInGLE
Single configuration file found
A single configuration file has been found. Press ā€œEā€ to confirm
and start the configuration process. Press any other key to
abort the process. If no keys are pressed within 10 seconds, the
process is, again, automatically aborted.
USB
COnFIG
Counter is being configured
The counter is configured using the file it has found.
USB
no CFG
No configuration command executed
A configuration file has been found and the configuration
started, but no command has been executed. Very probably,
the file does not contain any configuration commands (com-
ments not excluded).
USB
donE
Configuration complete
The configuration was completed without error. In order to re-
configure the counter, remove the USB drive and insert again.
USB
E1
Error 1: Drive was removed before configuration started
A configuration file was found, but the interface could no lon-
ger detect a drive when the configuration process was started
manually. The process is aborted and a restart prevented since
no configuration has taken place. The display returns to stan-
dard view after a couple of seconds.