Datasheet

Dimensions and specifications may be changed without prior notice
No. of cores: 1 to 61
Cross-section: 1.5 mm² to 240 mm²
Temperature range: exing: -5°C to +50°C,
xed installation: -40°C to +70°C
No. of cores: 1 to 5
Cross-section: 16 mm² to 630 mm²
Temperature range: exing: -5°C to +50°C,
xed installation: -40°C to +70°C
NAYY Power Cable
0.6/1kV, Aluminium, VDE approved
NYY Power Cable
0.6/1kV, Copper, VDE approved
With power cables, you have the choice - copper or aluminium
Connecting cable - from the inverter to the grid
HELUKABEL
®
supplies a wide range of connecting cables for wiring the
inverter to the grid. With a wide range of stock and the most modern
logistics centre in the cable industry, we can deliver directly to the customer’s
location, quickly and on time. www.helukabel.com/power-cables
Part no.
No.cores x
cross-sec.
mm²
Sheath
colour
Outer Ø
app. mm
Cop.
weight
kg / km
Weight
app. kg /
km
AWG no.
713529 1 x 2.5 black 5.0 24.0 41.0 14
713544 1 x 2.5 blue 5.0 24.0 41.0 14
713543 1 x 2.5 red 5.0 24.0 41.0 14
713530 1 x 4 black 5.4 38.4 55.0 12
713546 1 x 4 blue 5.4 38.4 55.0 12
713545 1 x 4 red 5.4 38.4 55.0 12
713531 1 x 6 black 6.2 57.6 82.0 10
713570 1 x 6 blue 6.2 57.6 82.0 10
713569 1 x 6 red 6.2 57.6 82.0 10
713532 1 x 10 black 7.4 96.0 123.0 8
713572 1 x 10 blue 7.4 96.0 123.0 8
713571 1 x 10 red 7.4 96.0 123.0 8
SOLARFLEX
®
-X H1Z2Z2-K
1500 V DC, EN 50618
Nominal voltage
AC 1 kV / DC 1.5 kV
Application
The SOLARFLEX
®
-X is used for cabling solar panels. = Product conforms with Low-Voltage Directive 2014/35/EU.
Technical data
Temperature range
-40°C to +90°C
max. temperature at conductor +120°C
Nominal voltage
AC 1.0/1.0 kV / DC 1.5/1.5 kV
Test voltage
AC 6.5 kV
Minimum bending radius
fixed installation 5x cable Ø
Cable structure
Tinned copper conductor, fine wired acc. to
DIN VDE 0295 cl.5, IEC 60228 cl.5
1
st
core insulation: special cross-linked compound
2
nd
core insulation: special cross-linked compound
Sheath colour: see table
Properties
Double-insulated
Complies with protection class II
UV-resistant
Ozone-resistant
Tests
Halogen-free acc. to
EN 50267, IEC 60754
Flame retardant acc. to IEC 60332-1-2
Smoke density acc. to IEC 61034
Weathering/UV-resistant acc. to EN
50618 Annexe E
EN 50289-4-17 Method A
Ozone-resistant acc. to
EN 50396 Clause 8.1.3 Method B
Approvals
EN 50618
TÜV Rheinland 2 PfG 1990/05.12
TÜV R60115689