Datasheet
H05Z-K / H07Z-K rubber insulated single core, halogen-free
PropertiesCable structureTechnical data
Ⴠ Bare copper conductor, finewire stranded
according to DINVDE0295 cl.5, BS6360
cl.5, IEC60228, HD383
Ⴠ ჀRubber-insulated single core cables for low
emission of smoke and corrosive gases in
case of fire to VDE0282 part9 and
HD22.9S2
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquersჀ Core identification according to
DINVDE0293 TestsჀ Conductor resistance
according to DINVDE0295 cl.5
Ⴠ Separator over conductor permitted
Ⴠ self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
Ⴠ Temperature range
-40 °C to +90 °C
Ⴠ Core insulation of cross-linked polyolefin,
compound type EI5 to DINVDE0282 part1
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Ⴠ Permissible working temperature
at the conductor +90 °C
Ⴠ Core colors see table below,
dark blue and orange on request
Ⴠ Ozone resistant according to EN60811-2-1
/ HD505.2.1
Ⴠ Nominal voltage
H05Z-K U
0
/U 300/500 V
H07Z-K U
0
/U 450/750 V
Ⴠ LS0H = Low Smoke Zero Halogen-free.
Ⴠ Smoke density according to VDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (equivalent
DINVDE0472 part816)
Ⴠ Test voltage 2500 V
Ⴠ Minimum bending radius
approx. 8x core ø
Note
Ⴠ Radiation resistance
up to 20x10
6
cJ/kg (up to 20 Mrad)
Ⴠ AWG sizes are approximate equivalent
values. The actual cross-section is in mm².
Application
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets
are to protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed
installation ducts. The direct operating voltage is permitted up to 900 V against ground when they are used in rail-coaches. For the inner
wiring of switch boards and distributors are to be used with an alternating nominal voltage up to 1000 V or a direct voltage up to 750 V
against ground.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
H05Z-K
u-blueogyedk-buviogreywhiteredbrownbluegn-yeblack
Weight
approx.
kg/km
Cop.
weight
kg/km
Core Ø
min. - max.
mm
Cross-
section
mm²
530715294652880529455287952878528775287652875528745287352872Part no.
------------9,04,82,1 - 2,60,5
530725294852889529475288852887528865288552884528835288252881Part no.
------------12,47,22,2 - 2,80,75
530735295052898529495289752896528955289452893528925289152890Part no.
------------15,09,62,4 - 2,91
H07Z-K
u-blueogyedk-buviogreywhiteredbrownbluegn-yeblack
Weight
approx.
kg/km
Cop.
weight
kg/km
Core Ø
min. - max.
mm
Cross-
section
mm²
530745295251776529515177551774517735177251771517705176951768Part no.
------------24,014,42,8 - 3,51,5
530755295451785529535178451783517825178151780517795177851777Part no.
------------35,024,03,4 - 4,32,5
530765295651794529555179351792517915179051789517885178751786Part no.
------------51,038,03,9 - 4,94
530775295851803529575180251801518005179951798517975179651795Part no.
------------71,058,04,4 - 5,56
530785296051812529595181151810518095180851807518065180551804Part no.
------------118,096,05,7 - 7,110
530795296251821529615182051819518185181751816518155181451813Part no.
------------180,0154,06,7 - 8,416
530805296451830529635182951828518275182651825518245182351822Part no.
------------278,0240,08,4 - 10,625
530815296651839529655183851837518365183551834518335183251831Part no.
------------375,0336,09,7 - 12,135
530825296851848529675184751846518455184451843518425184151840Part no.
------------560,0480,011,5 - 14,450