Datasheet

H07RN-F
rubber-sheathedcable
PropertiesCablestructureTechnicaldata
Resistantto Barecopperconductor,to
DINVDE0295cl.5,finewire,
BS6360cl.5,IEC60228cl.5
RubbersheathedcableH07RN-Fto
DINVDE0285-525-2-21,BS7919
DINEN50525-2-21,IEC60245-4
Weather
Tests
Temperaturerange
flexing-25°Cbis+60°C
fixedinstallation-30°Cbis+60°C
CoreinsulationofrubberEI4to
DINVDE0207-363-1/DINEN50363-1
Self-extinguishingandflameretardant
acc.toDINVDE0482-332-1-2,
DINEN60332-1-2,IEC60332-1-2
(equivalentDINVDE0472part804
testmethodB)
CoreidentificationtoDINVDE0293-308
-upto5corescoloured
-from6cores,blackwithcontinuous
whitenumbering
Permissibleconductoroperating
temperature +60°C
Nominalvoltage
U
0
/U450/750V
incaseofprotectedandfixedinstallation
U
0
/U600/1000V
Ozoneresistantoftheinsulationto
DINVDE0473-396,DINEN50396
GN-YEconductor,3coresandabove
Coresstrandedinlayerswith
optimallaylength
Oilresistanttestacc.to
DINVDE0473-811-404,
DINEN60811-404
OutersheathofrubberEM2to
DINVDE0207-363-2-1/DINEN50363-2-1
Max.permissibleoperatingvoltagein
threephaseandonephasea.c.system
U
0
/U476/825V
directcurrent-system
U
0
/U619/1238V
Note
Sheathcolour:black
G=withGN-YEconductor
x=withoutGN-YEconductor
Testvoltage
2500V
AWGsizesareapproximateequivalent
values.Theactualcrosssectionisinmm².
Permanenttensileload
max.15N/mm²
Thecoreidentificationofasinglecore
sheathed,ofaninsulatedwireisblack.
Minimumbendingradius
forfixedinstallation4xcableØ
forguidingoverroller7,5xcableØ
duringwindingondrums5xcableØ
adaptedtoVDEwith
designation07RN-F
-Part.-no.37094,19G1,5mm²
-Part.-no.37098,19G2,5mm²
-Part.-no.34349,5G120mm²
-Part.-no.34127,5G150mm²
Application
Heavydutyrubber-sheathedflexiblecablesaresuitedforuseformediummechanicalstressindry,dampandwetareasaswellasinopenairandin
agricultureplants.Theyareusedforequipmentinindustryworkssuchasboilers,heatingplates,handlamps,electrictoolssuchasdrills,circularsaws
andhomeworktoolsaswellasfortransportablemotorsormachinesatsite.Thesecablesarealsosuitableforfixedinstallationonplaster,intemporary
buildingsandresidentialbarracks.Theyaresuitablefordirectlayingoncomponentsandmechanicalpartsofmachines,forexampleliftsandcranes.
Theycanbeusedincaseofprotectedandfixedinstallationintubesorinequipmentaswellasrotorconnectingcableofmotorswithaworkingvoltage
upto1000Valternatingvoltageoradirectvoltageupto750Vagainstground.
=ProductconformswithLow-VoltageDirective2014/35/EU.
AWG-No.Weight
app.kg/km
Cop.
weight
kg/km
OuterØ
min.-max.
mm
No.coresx
cross-sec.
mm²
Partno. AWG-No.Weight
app.kg/km
Cop.
weight
kg/km
OuterØ
min.-max.
mm
No.coresx
cross-sec.
mm²
Partno.
1658,014,45,7 -7,11x1,537001 1898,019,07,7 -10,02x137019
16135,029,08,5 -11,02x1,5370201471,024,06,3 -7,91x2,537002
12100,038,07,2 -9,01x437003 14193,048,010,2 -13,12x2,537021
12280,077,011,8 -15,12x43702210130,058,07,9 -9,81x637004
8230,096,09,5 -11,91x1037005 10330,0115,013,1 -16,82x637023
8586,0192,017,7 -22,62x10370246290,0154,010,8 -13,41x1637006
4420,0240,012,7 -15,81x2537007 6810,0307,020,2 -25,72x1637025
41160,0480,024,3 -30,72x25370262530,0336,014,3 -17,91x3537008
1750,0480,016,5 -20,61x5037009
2/0960,0672,018,6 -23,31x7037010
3/01250,0912,020,8 -26,01x9537011
4/01560,01152,022,8 -28,61x12037012
300kcmil1900,01440,025,2 -31,41x15037013
350kcmil2300,01776,027,6 -34,41x18537014
500kcmil2950,02304,030,6 -38,31x24037015
600kcmil3600,02880,033,5 -41,91x30037016
750kcmil4600,03840,037,4 -46,81x40037017
1000kcmil6000,04800,041,3 -52,01x50037018
Continuation
27.09.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.