Datasheet

H07 V-K / (H)07 V-K PVC-Single Cores, fine wire stranded
PropertiesCable structureTechnical data
Bare copper fine wire stranded to
DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
PVC single cores to DINVDE0281 part3,
HD21.3S3 and IEC60227-3
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Temperature range
flexing -5 °C to +70 °C
fixed installation -30 °C to +80 °C
PVC core insulation, compound TI1 to
DINVDE0281 part3, HD21.3S3 and
IEC60227-3
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Nominal voltage U
0
/U 450/750 V
Core colours see below
Test voltage 2500 V
Core Identification with nominal
voltage U
0
/U450/750 V
Insulation resistance
min. 10 MOhm x km
Note
The following colours are recommended
(only single colour): black, white, blue, grey,
Minimum bending radius
12,5 to 15x cable ø
Colours yellow, green, transparent only in
(H)07 V-K available.
brown, red, orange, turquoise, violet and
pink. Two-coloured combinations are not
allowed, with exceptions of green-yellow.
Radiation resistance
up to 80x10
6
cJ/kg (up to 80 Mrad)
Two-coloured combination is only
permitted for (H)07 V-K.
Colour code Single core cables H07
see Technical Informations
Application
These insulated wires are suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits.
These are not allowed to install for direct laying on cable trays, channels or tanks. These types are permitted for the inner wiring of equipment,
distributor and switchboards and also for protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to
750 V direct current against earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
H07 V-K, (H)07 V-K/mm²
u-blue2-col.ogdk-butransgreenpinkyeviogreywhiteredbrownbluegn-yeblack
Cop.
weight
kg/km
Outer Ø
min. - max.
mm
Cross-
section
mm²
5002-20035010-601830151021400570019003300080035015-9005
approx. RAL
Coil in cardboard (100m)
Packing
H07 V-K
2639529144**2914229141291402913929138291372913629135291342913329132291312913029129Part no.
14,42,8 - 3,41,5
26396291602915829157291562915529154291532915229151291502914929148291472914629145Part no.
24,03,4 - 4,12,5
26397291762917429173291722917129170291692916829167291662916529164291632916229161Part no.
38,03,9 - 4,84
26398291922919029189291882918729186291852918429183291822918129180291792917829177Part no.
58,04,4 - 5,36
Spool (with various capacity)
Packing
H07 V-K
2639926705**2670326702267012670026699266982669726696266952669426693266922669126690Part no.
14,42,8 - 3,41,5
26400267212671926718267172671626715267142671326712267112671026709267082670726706Part no.
24,03,4 - 4,12,5
26401267372673526734267332673226731267302672926728267272672626725267242672326722Part no.
38,03,9 - 4,84
26402267532675126750267492674826747267462674526744267432674226741267402673926738Part no.
58,04,4 - 5,36
Continuation
K 8
K

Summary of content (1 pages)