Download
In most outdoor or difficult-to-heat heat areas, there are 2 options when looking at the size and quantity
of the heater required. Option 1 is to comfort heat the entire area based on the total dimensions of the
space, regarding of whether the entire area is being fully occupied. Spot heating will allow the area to be
“zoned”, meaning heating only the areas that are being used, such as tables in a restaurant or outdoor
alfresco area.
Option 2 for spot heat the high use areas, such as over outdoor tables, lounges, assembly lines or indoor
workstation.
INSTALLATION REQUIREMENTS
1.Qualified installer:
Electrical installation certificate shall be held by professional installation personnel, the installation process
should meet the national electrical safety standards.
2.Installation conditions:
a) Supply voltage fluctuation range should be within 土 10%. If it does not meet requirements, please revise
before installation.
b) If there is a serious security risk in user’s electricity environment, the installation should be refused until
security risks are eliminated.
c) Electricity lines should be well equipped with earth leakage protection devices and master switch.
d) Ground wire should be connected to the grounding device on the building. If not, please consult to
professional installer. Note: Please do not put ground wire to gas pipe, water pipe, lightening rod or
telephone grounding wire.
Electrical Parameters Table
Model No.
Power(W)
Rated Current(A)
Voltage(V)
APH2400R
2400
10.5
230