Magnetic stirrer MR Hei-Standard, MR Hei-Tec M1M3_108 Safe Heating and Mixing Translation of the original operating instructions Operating instructions must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference.
Overview MR Hei-Standard A
Contents Overview .................................................................................................. B Scope of supply MR Hei-Standard ......................................................................................................................... D Scope of supply MR Hei-Tec .....................................................................................................................................E Key to illustrations .....................................................
MR Hei-Standard Scope of supply MR Hei-Standard Accessories (optional) Scope of supply MR Hei-Standard As standard (EU): 505-20000-00 (230 V, 50/60 Hz) For US: 505-20000-01 (115 V, 50/60 Hz) For UK: 505-20000-02 (230 V, 50/60 Hz) For IN: 505-20000-18 (230 V, 50/60 Hz) + Power cord As standard (EU): 14-007-003-81 (230 V, 50/60 Hz) For US: 14-007-045-10 (115 V, 50/60 Hz) For UK: 14-007-005-45 (230 V, 50/60 Hz) For IN: 14-300-009-36 (230 V, 50/60 Hz) + Operating instructions 01-005-005-39 C
MR Hei-Tec Scope of s upply MR He i-Tec Accessories (optional) Scope of supply MR Hei-Tec As standard (EU): 505-30000-00 (230 V, 50/60 Hz) For US: 505-30000-01 (115 V, 50/60 Hz) For UK: 505-30000-02 (230 V, 50/60 Hz) For IN: 505-30000-06 (230 V, 50/60 Hz) + Power cord As standard (EU): 14-007-003-81 (230 V, 50/60 Hz) For US: 14-007-045-10 (115 V, 50/60 Hz) For UK: 14-007-005-45 (230 V, 50/60 Hz) For IN: 14-300-009-36 (230 V, 50/60 Hz) + Operating instructions 01-005-005-39 D
MR Hei-Tec E
Key to illustrations MR Hei-Standard (page A, C) 1 2 3 4 Hotplate Mains switch: Switch device on/off Speed control knob: Set set speed LED I/O: Device on/off 5 Heating button: Switch heating function on/off 6 7 8 9 10 11 12 13 LED light for heating function: Device heats up/does not heat up Temperature control knob: Set set temperature Drill hole for support rod with protective cap Temperature sensor socket Power plug Support rod Temperature sensor Pt 1000 Attachment with cable inlet MR Hei-Tec (page
Applied standards and guidelines EC declaration of conformity NOTICE See the "EC declaration of conformity" enclosed. Safety instructions WARNING Risk of injury due to failure to observe safety signs and safety instructions! Dangers emerge when safety signs, located on the device, are not observed or when safety instructions detailed in the operating instructions are not followed. Please note the safety signs. Please carefully read and observe the safety instructions provided.
General safety instructions The device has been constructed according to state-of-the-art technology and recognized safety regulations. However, risks may still arise during installation, operation and maintenance. Please observe the safety instructions and warning notices. The safety instructions provided in this chapter are supplemented by specific warning notices in the following chapters.
Operating personnel’s obligations Ensure that work which uses naked flames is not carried out in the vicinity of the device (risk of explosion). Ensure that the flow rate when removing liquids with flammable materials remains at < 1 m/s (electrostatic charge; risk of ignition). Ensure that gases classified in explosion group IIC are not produced by materials or during chemical reactions, e.g. hydrogen.
Information on the device Note Meaning Name plate (example: MR Hei-Tec) Warranty seal Warning Before opening the box disconnect power plug. Warnung Vor dem Öffnen des Gehäuses Netzstecker ziehen. Note: please disconnect the connection to the power supply before opening the device.
Residual dangers Despite all precautions taken, residual risks can emerge which may not be immediately obvious! Adhering to the safety instructions, the intended use and the operating instructions as a whole can reduce residual risks! WARNING Risk of slipping! Risk of injury. After operation or in the event of malfunctions, there may be liquid on the floor close to the machine. Watch out for any wet spots and clean the floor if necessary. WARNING Errors! Risk of injury.
WARNING Unauthorized access is prohibited! Risk of injury. Risks arise if unauthorized persons enter the danger zone of the device. The operator is responsible for ensuring that unauthorized persons (e.g. visitors) do not have access to the danger zones (service area, protected areas). DANGER Failure to observe the danger zone, work area and service area! Dangers are posed by electrical and mechanical energies, as well as by residual dangers.
Device description The device is a magnetic stirrer and has the following functions: Stirring of substances. Heating of substances. Stir and/or heat the substances in a heat-resistant stirring container, with the underside on the hotplate. Set the stirring speed and heating temperature individually using the operating elements. Storage & transport CAUTION Damages as a result of improper transport! Damage can be caused to the device and the device mechanics in the case of improper transport.
Accessories (optional) Temperature sensor Pt 1000 (DIN EN 60751, Class A) NOTICE Immersion depth of temperature sensor Immerse the temperature sensor in the medium by at least 20 mm. Otherwise inaccurate measurements are possible. The temperature sensor Pt 1000 measures and regulates the temperature of the heated medium. 1. Switch off the device. 2. Connect temperature sensor. Heat-On block Securely position the heat-on block.
Heat-On 5 liter block (when using a support rod) Mount support rod with an extension arm. Start-up CAUTION The mains voltage and specification of the mains voltage on the name plate do not coincide! Damage to property as a result of overvoltage. Please ensure that the mains voltage coincides with the voltage specified on the name plate. CAUTION Unintentional switch-on of the device! Injury and burns to the hands. Switch off the device. Remove the mains plug after use.
DANGER Risk of electric shock or a short circuit! Risk of electric shock or short circuit due to melted insulation Ensure that all mains cables, pipes and connecting cables have been laid correctly in the area where heat is generated. 1. Switch off the device. 2. Insert device connection cable in the mains power plug. 3. Insert device connection cable in the power supply socket. 4. Switch on the device.
Operation Stirring MR Hei-Standard NOTICE Start stirring function The stirring function starts from a speed of 100 rpm. You can adjust the speed up to a speed of 1400 rpm. 1. Set set speed.
MR Hei-Tec 1. Set set speed. Example: 150 rpm Stirring function switched on? If you have already switched on the stirring function at this point in time, the appliance adjusts to the set value immediately. Acceptance of the set value The set value is accepted automatically after a few seconds or by pressing the rotating push button Hei Guide.
2. Switch on stirring function. Example: 150 rpm Heating NOTICE Set temperature setting value You can set the set temperature anywhere between 20 to 300 °C. 1. Switch off the device.
2. Select heating method a. or b. MR Hei-Standard a. Heating without temperature sensor b. Heating with temperature sensor The temperature is measured and regulated exclusively using the hotplate. NOTICE The actual temperature in the stirring container is always lower than the preset set temperature.
4. Set set temperature. Example: 50 °C 5. Switch on heating function.
MR Hei-Tec a. Heating without temperature sensor b. Heating with temperature sensor The temperature is measured and regulated exclusively using the hotplate. NOTICE The actual temperature in the stirring container is always lower than the preset set temperature. Factors to consider for temperature differences are the following: heat transfer resistance of the different stirring containers, heat transfer resistance of the quantity to be heated and heat loss due to radiation.
4. Set set temperature. Example: 60 °C Display element „ext“ If the temperature sensor is connected, the display element "ext" is also shown. Heating function switched on? If you have already switched on the heating function at this point in time, the appliance adjusts to the set value immediately. Acceptance of the set value The set value is accepted automatically after a few seconds or by pressing the rotating push button Hei Guide.
5. Switch on heating function. a. Heating without temperature sensor b. Heating with temperature sensor Example: 60 °C Fast-Mode and Precise-Mode You can choose between the following 2 modes as soon as you have switched on the heating function: The time saving Fast-Mode (factory setting) – allows for shortest heating-up times. The Precise-Mode - prevents an overtemperature situation categorically.
Display of set speed and set temperature (MR Hei-Tec) Readout the set speed and set temperature. Display element „ext“ If the temperature sensor is connected, the display element "ext" is also shown.
Calibrating (MR Hei-Tec) With the calibrating function, you can change the temperature of the medium measured using the temperature sensor Pt 1000 by a calibration value of -5 °C to +5 °C. Stirring function and heating function The stirring function and the heating function may not be active. 1. Connect temperature sensor (see chapter "Installation" – "Accessories (optional)" - „Temperature sensor Pt 1000"). 2. Calibrate temperature.
3. When you reach the desired setting, release the Hei Guide rotary-push button. Save settings The last selected settings remain saved following switching off and are offered to you first when setting again the calibrating function. Safety Plus (MR Hei-Tec) The Safety Plus function allows you to switch off error monitoring of the temperature sensor for errors "E21" and "E22" and back on again if required (default setting: "SAF On").
a. Switch off Safety Plus function b. Switch on Safety Plus function 3. Press Heating button again. 3. Press Heating button again. 4. When you reach the desired setting, release the Hei Guide rotary-push button. Save settings The last selected settings remain saved following switching off and are offered to you first when setting again the Safety Plus function.
Error codes Error code displayed on the device NOTICE 1. Perform a reset. 2. Implement the measures suggested in the table below. MR Hei-Standard Error code Cause LED I/O flashes one time - LED I/O flashes two times The actual temperature exceeds the set temperature on the sensor of the temperature sensor by more than 25 °C: Consequence Heating function off. Measure Please contact our Technical Service. Check test setup. Please contact our Technical Service. a. Temperature control defective.
Error code Mode „E21“ * Cause Consequence Measure a. Temperature sensor dropped from the medium. Position the temperature sensor at the measuring point. Perform a reset. b. Cool medium is refilled when heating function is switched on and temperature sensor is connected. Perform a reset. (IMPORTANT: Only refill the cool medium when the heating function is switched off). „E23“ (only in Precise-Mode) „E22“ * a. Temperature sensor located outside of the medium when switching on the heating.
Maintenance The device is maintenance-free. Is repair work required? Please inform Heidolph Instruments. Repair work must be carried out by the specialized personnel authorized by Heidolph Instruments. DANGER Risk posed by electrical voltage! Risk of damage to health and to the device. Remove mains plug before opening the instrument. Cleaning CAUTION Damage to property as a result of corrosive cleaning agents! Damage to the surface of the device.
Accessories Heat-On 250 ml block 505-80067-00 Heat-On 250 ml block with flask sidearm cutouts 505-80067-01 Heat-On 500 ml block 505-80069-00 Heat-On 1 liter block 505-80071-00 Heat-On 2 liter block 505-80073-00 Heat-On 3 liter block 505-80075-00 Heat-On 5 liter block 505-80076-00 Heat-On safety handles 505-80077-00 Heat-On inserts from 10 ml to 150 ml on request Concave block adaptor for 1 liter flasks 504-94000-00 Heating bath liquid 5 liter – up to 240°C 515-31000-00 Support rod, stain
* Temperature setting accuracy of external sensors ± 0.5 K * Temperature setting accuracy of hotplate sensors ± 0.5 K * Speed 100 – 1400 rpm Speed accuracy <2% Maximum stirring quantity (water) 20 l Connection Temperature sensor sets the control accuracy for the following values: 800 ml water in a 1 liter glass beaker, form H according to DIN 12 331, set temperature 50 °C, 40 mm stirring bar, 600 rpm, immersion depth of sensor 60 mm.
Warranty bond The Heidolph Instruments company provides a 3-year warranty for the products described here (excluding glass and wearing parts) if you register using the warranty card enclosed or online (www.heidolph.com). The warranty is valid from the point of registration. The serial number is also valid without registering. The warranty covers part and manufacturing defects.
Confirmation of condition of unit In the case of repair, copy and complete the Conformation of condition of unit and send it to Heidolph Instruments (see chapter "Contact/Technical Service"). 1. Details about the unit Product number Serial number Reason for repair 2. Has the device been cleaned, decontaminated/sterilized? yes no 3.
30
M_83 01-005-005-39-1 21.03.2014 © Heidolph Instruments GmbH & Co. KG We reserve the right to make any technical modifications without prior notification. This documentation is not subject to revision; the latest versions of this documentation are found on our homepage. The copyright for all texts and images is held by Heidolph Instruments GmbH & Co. KG.