Hei-VAP Precision Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership Operating Instruction Hei-VAP Precision Operating instruction must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference.
Contents About this document 5 About this manual....................................................... 5 Basic safety instructions 10 General Safety.......................................................... 10 Intended use............................................................ 10 Unit Description 18 Unit Description........................................................ 18 Set-up and start-up 19 Scope of delivery....................................................... 19 Transport.........
Contents About this Document Gradient function....................................................... 76 Softkeys................................................................... 78 More Functions.......................................................... 81 Setup...................................................................... 82 Menu topology.......................................................... 83 Errors and troubleshooting 87 General Errors.................................................
About this Document Icon Designation Death RISK This signal word must be used, if death or irreversible health impairments may develop when the non-compliance of operator regarding the hazard warning.
About this Document About this Document Verbotszeichen Icon Images Explanation Icon Explanation Fire, open flame and smoking prohibited Prohibition for people with metal implants Prohibition for persons with a pacemaker extinguishing with water is prohibited Item numbers in the images in the text are conveyed in parentheses. If no image number is listed, the item number refers to the image/graphic directly above the text.
Basic safety instructions Basic safety instructions The rotary evaporator is constructed according to the current state of the art and accepted safety regulations. However, risks still exist during the installation, operation and maintenance of the product. Observe safety instructions and warnings. The basic safety instructions in this chapter are supplemented in the following chapters of the operating instructions by concrete warnings.
Basic safety instructions Basic safety instructions Responsibilities of the operating personnel Verify that the distillation material can be evaporated safely and that the distillation residue is not explosive. Verify that work using an open flame is not conducted in the surroundings of the rotary evaporator (explosion risk). Verify that the flow rate of < 1 m/s is guaranteed when suctioning liquids that contain combustible materials (electrostatic charge; ignition risk).
Basic safety instructions Basic safety instructions Signs on the equipment Sign WARNING Danger of slipping! Risk of injury. Designation The floor near the machine may be dirty after the operation or during malfunctions in the machine. Water from the bath may spill or condensation from coolant may drip on to the floor near equipment. Watch for contaminated areas and clean the floor, if necessary. Hot surface Risk of entanglement WARNING Hot surfaces! Scalding and burns.
Basic safety instructions WARNING Basic safety instructions Risk of injury from operational noise! DANGER Hearing impairment from the continuous sound pressure level of the equipment may occur. Serious risk of injuries. Residual electrical energy remains in the electrical wires, equipment and machines, when the evaporator is switched off. Inform operating personnel of outlets. Disconnect the sockets from the power source to completely de-energize.
Unit Description Set-up and Start-up Unit Description Scope of delivery Rotary evaporators Hei-VAP Value, Hei-VAP Advantage, Hei-VAP Precision serve the ▪ ▪ ▪ ▪ Standard coated or Hei-VAP Value or Hei-VAP Value or Hei-VAP Value or Hei-VAP Advantage 561-01110-00 562-01100-00 562-01110-00 or Hei-VAP Advantage 561-01300-00 561-01310-00 562-01300-00 562-01310-00 or Hei-VAP Advantage 1 561-01500-00 561-01510-00 562-01500-00 562-01510-00 or Glassware set Hei-VAP Advantage G6 ret
Set-up and Start-up Glassware set G1 1 513-00100-00 513-00140-00 or Glassware set G3 1 513-00300-00 513-00340-00 or Glassware set G5 1 513-00500-00 513-00540-00 or Accessories Glassware set G6 1 513-00600-00 513-00640-00 or Order No. NS 24 / 40 Glassware set G1 coated 1 513-00110-00 513-00150-00 or Order No.
Set-up and Start-up Set-up and Start-up Attaching the transportation protection device before packing All hose and cable connections to other devices and the coolant/vacuum connection are disconnected. Connecting the unit 1. Continue pressing the lift position contact down when switching the unit on (this will suppress the “lift to the top when power off” function). 2. Move the hoist down by using the “hoist down” (4) button 3.
Set-up and Start-up Set-up and Start-up Avoid setting up the rotary evaporator in corrosive atmospheres. This reduces the service life of the equipment. CAUTION Tilting the heating bath! 1. Place the base plate (2) on the surface for the heating bath (1) into the provided rail, so that the heating bath cannot tilt. 2. Place the heating bath into the rails by its feet. Be careful that the heating bath connection points to the right rear. Fill the heating bath Damaging the housing and risk of injuries.
Set-up and Start-up Set-up and Start-up Heating bath set-up when using Chiller Glassware sets Assemble glassware sets Assembling the glassware sets will be described in the following. The rotary evaporators can be equipped with various glassware sets. 1 2 The base unit is set up and installed. A water or coolant connection is available (does not apply for glassware set G5). Lift is in the top position (see chapter Set-up and start-up).
Set-up and Start-up Set-up and Start-up Install the condenser mounting Install the vapor tube In order to protect the glassware sets with vertical condensers (G3 - G6) from accidentally tilting, they are supported by a condenser mounting and support rod. Moreover, the support rod shall be used to fixate the vacuum sensor to all glassware sets. The evaporator flask and the vapor tube are connected with the condenser and the rotation of the evaporator flask is made possible by the drive unit.
Set-up and Start-up Set-up and Start-up 1 2 3 3. Continue to press the locking button (Figure 4-8 (1)). 4. Remove the screw coupling connection of the vapor tube (Figure 4-7 (6)) from the drive unit. 5. Pull out the clamping sleeve (Figure 4-7 (5)). 6. Push the vapor tube coupling clamp (Figure 4-7 (6)) and clamping sleeve (Figure 4-7 (5)) with the bead first to the vapor tube (Figure 4-7 (7)). Verify that the bead audibly snaps into the groove of the vapor tube (Figure 4-7 (7)). 7.
Set-up and Start-up Set-up and Start-up Install the condenser 1 The threaded clamping screw is removed from the drive head. Spring is removed from the drive head. The vapor tube is installed on the drive. PTFE 26 vacuum seal is installed on the vapor tube. Support rod is installed. WARNING 2 3 Glass breakage! 4 Serious injuries from shattering and breaking glass. Check glass devices for damages (stars, breaks, etc.). Only use perfect glass devices and replace all damaged glassware as soon as possible.
Set-up and Start-up Set-up and Start-up Version glassware set G6 (condenser for return flow distillation): 1 1 2 2 3 4 5 6 3 Illustratiion 4-11: Glassware G6 ‒ ‒ ‒ ‒ ‒ ‒ 1 Center piece 4 Gasket G6 2 Threaded connection 5 G6 intermediate part (5) 3 Tension spring 6 G6 threaded coupling Push the threaded connection (2) over the condenser flange. Push the spring (3) over the condenser flange. Screw the G6 (6) gland on the drive head (Figure 4-10 (4).
Set-up and Start-up Set-up and Start-up Install the evaporator flask WARNING The correct seating of the swing clamp on the flange of the evaporator flask must be observed! Glass breakage! Serious injuries from shattering and breaking glass. Check glass devices for damages (stars, breaks, etc.). Only use perfect glass devices and replace all damaged glassware as soon as possible. Work carefully.
Set-up and Start-up Set-up and Start-up 1 2 1 Figure 4-14: Evaporator flask inclination / immersion depth 1. Grasp the condenser with the left hand. 2. Unlock the locking device (1) at the lift column toward the right by applying pressure with your right hand. 3. Set the evaporator flask inclination by carefully swinging the condenser. 4. Position the locking device by releasing and snapping it in.
Set-up and Start-up Set-up and Start-up Release the evaporator flask from the vapor tube WARNING Glass breakage! Serious injuries from shattering and breaking glass. WARNING Glass breakage! Check glass devices for damages (stars, breaks, etc.). Work carefully. Serious injuries from shattering and breaking glass. Check glass devices for damages (stars, breaks, etc.). Only use perfect glass devices and replace all damaged glassware as soon as possible. Work carefully. CAUTION WARNING 5.
Set-up and Start-up Set-up and Start-up Assemble the inlet tube Connect the cooling medium (except G5) Use a suitable tube with an inner diameter of 7-8 mm (i.e. hose set (see accessories “Accessories, spare parts” – “Accessories”)) 1 2 3 1 2 3 4 Figure4-16: Assemble the inlet tube 1 Inlet valve connection 3 Cap 2 Seal 4 Inlet tube 1. Guide the inlet tube (4) through the cap (3) and seal (2) assembled on the inlet valve connection (1). 2.
Set-up and Start-up 1 Set-up and Start-up 2 3 4 5 Suitable vacuum source is available. Suitable vacuum tube (7-8 mm) is available. 1 2 3 6 7 Figure 4-19: Vacuum connection Figure 4-18: Connect the Woulff flask with vacuum valve 1 Ferrule for the vacuum valve 5 Ferrule for the bottle 2 Cap nut 6 Mounting brackets 3 PTFE tube section 7 Screws 4 Threaded fitting cap 1 Threaded fitting cap 2 Connector (GL hose barb) 3 Vacuum tube 1.
Set-up and Start-up Set-up and Start-up 12 12 6 11 7 10 14 6 11 7 10 14 4 4 13 13 8 8 1 1 9 5 9 5 2 3 3 Figure 4-22: Hei-VAP Precision with Rotavac valve control and vacuum box Figure 4-23: Hei-VAP Precision with Rotavac valve control and vacuum box and with Woulff bottle 8 Ventilation / inert gas 1 Condenser 9 Vacuum tube 2 Vacuum valve cable connection 3 11 USB PC connection 12 Vacuum sensor connection Switch box connection 13 Vacuum sensor Hei-VAP connection 14 D
Set-up and Start-up Set-up and Start-up 11 11 5 10 6 9 13 5 10 6 9 13 12 12 7 7 3 4 4 1 3 1 8 8 2 2 Figure 4-24: Hei-VAP Precision with Rotavac vario tec and vacuum box 1 Condenser Vaccum pump connection 2 Woulff bottle USB PC connection 3 Condensate cooler (optional) 10 USB PC connection 11 Vacuum sensor connection 4 Vacuum valve cable 11 Vacuum sensor connection 12 Vacuum sensor 5 Switch box connection 12 Vacuum sensor 13 Data cable 6 Hei-VAP connection
Set-up and Start-up Set-up and Start-up Assemble / connect accessories Feed the distilled material 4 Additional distillation material can be supplied during the distillation under vacuum via the inlet tube and the inlet pipe. 6 1 2 1 Figure 4-26: Inlet tube 1. Place the inlet tube (1) in the additional distillation material. 2. Turn the stopcock (2) parallel to the inlet tube (1). The additional distillation material is suctioned into the evaporation flask while system is under vacuum.
Set-up and Start-up Set-up and Start-up The vapor temperature sensor cannot be used when using the temperature sensor Autoaccurate sensor. 1 1. Unscrew the threaded fitting on the condenser. 2. Insert the vapor temperature sensor so in the condenser that the white PTFE side of the seal (2) points to the glass thread. 3. Screw the vapor temperature sensor together with the threaded fitting. 4.
Set-up and Start-up Set-up and Start-up Vacuum box Connect the base unit CAUTION Supply voltage and the voltage information on model tag do not match! Damage due to incorrect voltage. 9 8 1 7 2 Verify that the voltage specified on the model tag corresponds with the mains voltage. Only disconnect the basic device with the heating bath if the device is de-energized. Unplug main power supply.
Set-up and Start-up Set-up and Start-up 1. Plug the socket of the heating bath connecting cable (2) of the Hei-VAP base into the appropriate connector (1). 2. Plug the socket (2) with the cap nut (3) of the heating bath connecting cable (7-pin) into the heating bath: - Press the socket into the connector so that the locking stub fits into the groove. - Grab the socket (2) on the cap nut (3) and turn the knurled nut clockwise to fix it. 3.
Switching on the base unit Operation Switching on the base unit Operating the control panel 1. Switch on the base unit by pressing the toggle switch of the power switch. 2. The power switch of the base unit must be in the “1” position. 2 Figure 4-31: Control panel (for Hei-VAP Precision) The control panel can be removed from the base unit. The 1.3 m connecting cable between the control panel and the base unit can be adjusted to the optimal length by a cable run and reel.
Operation Operation 1. Pull the control panel apart, so that the cable reel can be seen. 2. The cable reel is surrounded by a shell. 3. Pull the control panel apart, so that the cable reel can be seen. The cable reel is surrounded by a shell. 2. Reel in the cable to the desired length by wrapping the cable around the reel. 3. Press the shell to the control panel. The shell can be turned by 180° as desired, in order to adjust the surface and view to the control panel. 4.
Operation I. 1. Operation II. Version Hei-VAP Value, Hei-VAP Advantage, Hei-VAP Precision (hand lift) III. “click” 2x 2. 2. “click” 1. Push the hand lift (1) down and shift to the left (lower) or right (upward) while keeping the handle depressed. 2. Release the hand lift (1) at the desired position. The drive unit snaps into the appropriate position when released. 1. Version Hei-VAP Advantage, Hei-VAP Precision (motor lift) The base unit is installed. 1.
Operation Operation Operation of the Hei-VAP Precision The basic steps of operating the rotary evaporator Hei-VAP Precision will be explained in this chapter. The parameters for the distillation are set and monitored via the control panel. The set parameters are stored. The last used parameters will appear after a restart. The actual value display is always the start screen. All current actual values are displayed as large numbers and the target values as small numbers.
Operation Operation Setting the rotation speed (actual value displays of all modes) The unit is switched on. The rotation is switched off (pushbutton Rotation start/stop). Actual value display The range can be set from 10 - 280 [rpm] in 1 [rpm] increments. 100 [rpm] are set as default when shipping from the factory. 1. Select the entry “rotation” by turning the Hei-GUIDE (6) and call up the selected entry to be changed by pressing the Hei-GUIDE (6) again. 2.
Operation WARNING Operation Imploding glass devices!! Selecting the entry by turning the Hei-GUIDE (6) Serious injuries from shattering glass. 1. Call up the selected entry to be changed by pressing the Hei-GUIDE (6) (entry will be highlighted in orange). 2. Set the value by using the rotary pushbutton controller Hei-GUIDE (6). 3. Pressing it again confirms the change. Softkey “Esc“ (1) terminates the change of the currently processed entry. 4. The new settings are accepted by the “accept” entry.
Operation Operation Actual value display Autoeasy mode The required vacuum is automatically calculated based on a pressure measurement in the “AUTOeasy” mode. The boiling pressure is detected and maintained automatically. The “AUTOeasy” mode is configured for easy handling and for common heating bath and cooling media temperature. In case the amount of steam produced is insufficient and the evaporation does not start, increase the heating bath temperature.
Operation Operation Menu display The following values can be changed in the menu view: Heating bath Setting of the bath temperature. Setting range is between 20 °C and maximum heating bath temperature (MAX TEMP is adjustable in Setup) with a highest range of 210 °C. Rotation Setting of rotation speed of the distillation flask. Setting range is between 10 and 280 rpm. Distillation rate (dT) Setting of the distillation rate. Setting range is between 1 and 10.
Operation Operation Timing functions Storing the data record The vacuum control is not activated. Parameters are set. You are in the menu view of a mode (SETpressure, AUTOeasy, AUTOaccurate, gradient) Press softkey “Store Favorite“. The timer function stops the distillation after a set period. The setting range is adjustable from 1 - 1440 [min] in 1 minute. increments in the “timer” menu entry. Setting “off” is comparable to 0. The entry is set to lowercase letters with element “abc”.
Operation Operation Rename the data record The following values can be changed in the menu view: The name can be entered similar to the “save” function. The system checks for duplicates when naming. Heating bath Setting of the bath temperature. Setting range is between 20 °C and maximum heating bath temperature (MAX TEMP is adjustable in Setup) with a highest range of 210 °C. Copy data record Rotation Setting of rotation speed of the distillation flask. Setting range is between 10 and 280 rpm.
Operation Operation 1. Select the pressure/time step to be changed by turning the rotary pushbutton controller Hei-GUIDE (6). 2. Confirm the selection by pressing the Hei-GUIDE (6). 3. The value can be changed by turning the Hei-GUIDE (6) to the left or right. 4. The current setting is accepted by pressing the Hei-GUIDE (6). The data record can be saved by using softkey “Store Favorite“ (1). Softkey “Esc“ (1) discards the changes and returns to the actual value display.
Operation Operation Overview of all softkeys More Functions Softkey Function Store Favorite Storing the data record for Favorites (program list). Esc Cancelling the entry and backing up on step, no storage of changes Hold The vacuum is held at the value when soft key is depressed.
Operation Operation Setup Menu topology Online Help Shows Online-Help instead of the actual values in the menu SETpressure, AUTOeasy, AUTOaccurate, Gradient, Favorites and Setup. Safety pressure If the system reaches the setting of the Safety Pressure point, the vacuum control and flask rotation is stopped, the evaporator is vented and the motor lift is raised (ML only). Setting range is between 900 and 1200 mbar. Heating Bath Media Max. Temp.
Operation Operation Autoeasy Mode Gradient Menu entry Value range Menu entry Heating bath 20 °C and the max. temperature of the heating bath (to be assigned in Setup), however, no more than 210 °C. Heating bath 20 °C … max. temp. of the heating bath not higher than 210 °C.
Operation Errors and Troubleshooting General errors Favorites Menu entry Value range / status (empty) [name of Favorite] ▪ ▪ ▪ ▪ Apply Rename Copy Delete Error / message Cause Unit cannot be switched on Main plug not connected to the main power supply Connect the main plug with the power supply Fuses defective or blown fuse Replace fuses (see chapter “Maintenance, cleaning, service” – “Maintenance”) Master switch is deactivated Activate main switch Fuses defective or blown fuse Replace fus
Errors and Troubleshooting Errors and Troubleshooting Error / message Cause Motor lift is not functioning Master switch is deactivated Activate main switch Master switch is defective Contact service Fuses defective or blown fuse Replace fuses (see chapter “Maintenance, cleaning, service” – “Maintenance”) Lift is at end stop Activate other arrow key Mechanical system / motor is defective Contact service No evacuation Insufficient vacuum Remedy Height stop is not set accurately Perform heig
Errors and Troubleshooting Errors and Troubleshooting Hei-VAP Precision Error / message error text Cause The temperature sensor for calculating the vapor temperature is not connected, defective or the temperature is above the measured range. ‒ ‒ ‒ The vapor temperature sensor is defective or the temperature is below the measured range ‒ The Autoaccurate sensor is defective or the temperature is below the measured range.
Errors and Troubleshooting Error / message error text The set safety pressure was exceeded. Errors and Troubleshooting Cause ‒ Remedy Pressure sensor safety pressure is exceeded. Deactivate the unit Check if the pressure sensor has responded. If yes, reset (see chapter “Maintenance, cleaning, service” – “Maintenance”) Contact service The vacuum box is not connected or defective. ‒ Vacuum box is not connected or defective Check the connection between the vacuum box and the evaporator.
Maintenance, cleaning, service Maintenance, cleaning, service Maintenance 2. Press the maximum temperature limiter (1), possibly with a pointed object. Only use genuine parts approved by the manufacturer! The vapor tube and PTFE 26 vacuum seal must be routinely serviced. 1. Remove and clean the vapor tube and the PTFE 26 vacuum seal (see chapter “Set-up and start-up“ – “Glassware sets”). 2. Check the PTFE 26 vacuum seal for damages and wear, replace if necessary.
Maintenance, cleaning, service Maintenance, cleaning, service Readjust the vacuum seal (glassware set G6) 1 2 Figure 8-3: Fuse on the bottom of the unit Figure 8-2: Readjust the vacuum seal - glassware set G6 1 2 Valve Center piece G6 CAUTION Injuring and burning hands. The seal in the valve (1) can be readjusted with a screwdriver.
Maintenance, cleaning, service Dismantling, storage, disposal Cleaning WARNING Disassembly Damages due to corrosive cleaning agents! CAUTION Injuries to hands. Verify that the rotation is displayed. Damages on the surface of the unit. Use only mild soap solutions. Never use chlorine bleach or cleaning agents that are chlorine based. Never use abrasives, ammonia, cleaning rags or cleaning agents with metal parts.
Dismantling, storage, disposal Storage Remove the Woulff bottle WARNING Dismantling, storage, disposal Evaporator Glass breakage! Cuts. The unit may be stored in a dry location. Store the unit in the original packaging (only possible with the transportation protection device attached). Work carefully. Close the packaging with adhesive tape. Glassware set Remove the Woulff bottle in reverse sequence of the assembly (see chapter “Set-up and start-up” – “Glassware sets”).
Accessories, spare parts Accessories, spare parts Spare Parts 12/ 13 2 Glass devices 10 9 1 1 8 7 1 12/ 13 11 3 3 6 2 11 10 9 5 8 5 4 6 4 7 Figure 10-2: Glassware set G3 Figure 10-1: Glassware set G1 Order description Position Order No.
Accessories, spare parts Accessories, spare parts 14 15 1 1 13 12 2 17 16 11 10 9 8 2 3 3 5 3 6 4 1 7 16 Figure 10-3: Glassware set G5 Order description 3 Position Order No.
Accessories, spare parts Accessories, spare parts Order description Position Order No.
Appendix Appendix Technical data Heating Bath Hei-VAP Base unit Hei-VAP Value, Hei-VAP Value Digital Base unit Hei-VAP HL Base unit Hei-VAP ML Base unit Hei-VAP HL Base unit Hei-VAP ML Dimensions (WxDxH) of drive unit in the lowest position without a glassware set **** 393 x 449 x 427 mm 393 x 449 x 427 mm 393 x 411 x 427 mm 393 x 449 x 427 mm 393 x 411 x 427 mm Connected load 1400 W Connected voltage 230 V / 50/60 Hz oder 115 V / 50/60 Hz Drive unit EC motor with electronic speed contro
Appendix Appendix Unit configuration Hei-VAP Precision: Hei-VAP Value: ▪ Rotary evaporator Hei-VAP with valve-controlled vacuum pump ‒ Vacuum valve (optional Woulff bottle) and ROTAVAC valve control ‒ with vacuum valve (optional Woulff bottle) and ROTAVAC valve tec ▪ Rotary evaporator Hei-VAP with speed-controlled vacuum pump ‒ with ROTAVAC vario control ‒ with ROTAVAC vario tec ▪ Rotary evaporator Hei-VAP with vacuum ‒ with vacuum valve (optional Woulff bottle) and vacuum ▪ Expanded function of
Appendix Appendix Solvent data Total MW Vapor ΔHvap Vacuum for a vapor formula [g/mol] point [°C] [J/g] point at 40 °C [mbar] [mm(Hg)] Acetone C3H6O 58,08 56,5 550 556 387 Acetonitrile C2H3N 41,05 81,8 833 230 173 Benzene C6H6 78,11 80,1 549 236 177 n-butanol (butyl alcohol) C4H10O 74,12 117,5 619 25 19 tert.
Appendix Appendix EC Declaration of Conformity Declaration of non-objection Copy and mail / fax this declaration in the event of repairs to Heidolph Instruments GmbH & Co KG (see Chapter 8.4). EC Declaration of Conformity See attachment “EC Declaration of Conformity”. 1. Warranty Statement y l.: ( + 4 9 )- 9 1 2 92 vic 07 t r an Te s W a r r 2 9 4 Se rv J i 3 e ea Y S er e i 08 ah 7 .
Made in German y 01-005-004-92-2, 05.09.2014 © Heidolph Instruments GmbH & Co. KG Technical changes reserved. Publication not mandatory. This document is not part of an automatic content management system, newest versions of this document can be found on our website. Heidolph GmbH & Co. KG reserve the copyright for texts and pictures.