HF 708 ULTRASONIC HUMIDIFIER with Negative Ions ©2012 HF-Eng CAN | US | UK - HF 708 - 08/12
Thank you for purchasing the innovative Heaven Fresh HF 708 Cool Mist ultrasonic humidifier. We wish you many r. years of healthy indoor air with this efficient and effective product Ensure that all safety precautions are followed when using this electrical appliance for the proper operation of the device. These instructions describe the safety precautions to be observed during operation. They are designed to prevent injuries or damage to this device.
WHY HUMIDIFY THE AIR? When the air is dry, especially in the winter months, it can become unpleasant and even unhealthy, leading to increased levels of static electricity, dry skin, cracked lips and even noise bleeds. Optimal humidity is between 45 to 55% relative humidity. During the winter months though, relative humidity in the average home can drop to below 20%. Low humidity can lead to a variety of conditions that cause ill health.
PRODUCT SPECIFICATIONS Model: HF 708 Power supply: 220~240V 50Hz (Europe), 110~120V 60Hz (USA & Canada) Energy Consumption: 30W (Cool Mist) Water tank capacity: 6L (1.6 US gallons) Mist Evaporation Rate: ≥250ml/hr Room Coverage Area: 40 m² (430 ft²) Noise level: ≤35dB(A) Negative Ion Output: 3,000,000/cm³ (49,161,000/inch³) Dimensions (LxWxH): 23 x 22 x 34 cm (9.0 x 8.7 x 13.4 in) Weight: 2.89 kg (6.
COMPONENTS Major HF 708 components: Ionizer © Heaven Fresh Page 5 HF 708 Ultrasonic Humidifier
OPERATING INSTRUCTIONS Before getting started, please remove the HF708 from its box and allow it to become accustomed to the room temperature for at least 30 minutes especially if the machine is cold from the outside air. The HF 708 is designed to operate at temperatures between 5-40 ºC and relative humidity of less than 80%. To get started, grasp the water tank by the handle at the top and lift from the base.
OPERATING INSTRUCTIONS Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a bubbling sound as the air enters the water tank. Plug the power cord into the electrical outlet (NEVER SWITCH ON THE HUMIDIFIER WITHOUT WATER IN THE BASIN). Turning the Power Knob to “ON” will activate the humidifier and unit will start releasing cool mist.
TROUBLESHOOTING The following is a troubling shooting guide to help you solve any issues that may have with the operation of the HF 708. Trouble Possible reasons Solution Power lamp is off or does not work. Humidifier is not plugged into the power outlet. Connect power cord to electrical outlet and press power button. Power light is on but no mist No water in water tank. Fill water tank with water. The mist has a strange odour. A new machine.
TROUBLESHOOTING The following is not considered faulty operation: · If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water. · If you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal. · The machine operates very quietly but it is not completely silent. Noise levels less than 35 db is considered normal.
CLEANING AND MAINTENANCE You can ensure many years of trouble free operation of your HF 708 humidifier by following a few simple maintenance procedures. If your water is hard, containing high concentrations of calcium and other minerals, then over a period of time white dust will start to deposit on the various surfaces in the room. A white, film-like substance will also start to develop in the water basin, on the transducer and on the inner surface of the water tank.
CLEANING AND MAINTENANCE How to clean the water basin: 1. 2. 3. Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then soak the cloth with vinegar and repeat the process. If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush. Rinse the basin with clean water. How to clean the White Dust & Anti-Microbial Filter: 1. 2. 3. 4. Remove the filter from the water tank.
CLEANING AND MAINTENANCE If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly. Then wrap it in protective packaging and keep it next to the humidifier in a cool, dry and dark storage space. DISPOSAL OF THIS DEVICE At the end of the product life cycle, you should not throw this machine into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipment.
WARRANTY CERTIFICATE WARRANTY CERTIFICATE FOR HF 708 ULTRASONIC COOL MIST HUMIDIFIER with NEGATIVE IONS Date of purchase: Customers name: Address: Telephone: Email: Seller’s name: Address: 1. Please fill in completely this Warranty Certificate. Send it with the invoice and the unit, postage pre-paid and using the original packing box, to your distributor. Make sure to include the appropriate return postage for the package. 2.
WARRANTY INFORMATION Heaven Fresh products are subject to strict quality control before leaving the manufacturer. This allows our customers to benefit from repairs, replacement of parts and even replacements for free. What is covered: For how long: What we will do: All parts defective in material and workmanship. Three years from purchase date. Repair or replace any defective parts.
HF 708 Ultrasonic Humidifier