Wiring Diagram - Touch Carbon Volt Free Output
Thermostat & Time Clock Modes
NEUTRAL
LS & LR ARE NORMALLY THE
ROOM THERMOSTAT CONNECTIONS
MODBUS
INTERFACE
Model: Touch Carbon
LIVE
230V SUPPLY IN
VOLT FREE TO BOILER
230VAC
RT1 - A2 A1 N LA
This product must only be installed by a qualified electrician
and comply with local installation regulations.
Floor
Sensor
LS
LR
Touch Series
B