Instruction Manual
28
Model: Touch Carbon
Optional Settings - Feature Table
FEATURE
Viewing Accessory
Pairing Accessories
Temperature Format
Switching Differential
Output Delay
Up/Down Temperature Limit
Sensor Selection
Floor Temperature Limit
Optimum Start
Rate of Change
Program Mode
(DST) Daylight Saving
Communications ID
(Modbus)
Program Type
DESCRIPTION
Information only
Commences countdown from 99 – 00 seconds.
00 = °C, 01 = °F (00 = Default)
00 = 0.5°C, 01 = 1.0°C (Default) 02 = 2.0°C, 03 = 3.0°C
00 - 15 M
inutes (00 = Default)
00° - 10°C (00° = Default)
00 = Built in Sensor with optional wireless Remote Air (Default)
01 = Wireless Remote Air Only
02 = Floor Sensor Only
03 = Built in + Floor Sensor + optional wireless Remote Air
04 = Floor Sensor + Wireless Remote Air Only
20°C – 45°C (28°C Default)
00 = Disabled (Default) 01 = 1 Hour 02 = 2 Hours
03 = 3 Hours 04 = 4 Hours 05 = 5 Hours
Information Only
00 = 5/2 01 = 7 Day 02 = 24 Hour
03 = None programmable
00 = Disabled (D
efault) 01 = Enabled
01-32
00 = Disabled
00 = 4 Comfort Levels (Default) 01 = 6 Comfort Levels
SETTING
A
P
01
Menu
Entry Point
02
03
04
05
06
07
08
09
10
11
12
13
Back-light Dimming
00 = Medium 01 = Low