Instructions / Assembly

20
1. Turn gas supply OFF by turning propane tank valve clockwise to close.
2. Turn control knob (40) clockwise to OFF position.
3. Disconnect the power cord once the heater has cooled to ambient temperature.
TO STOP HEATER
OPERATION MODEL NO.SRCH11033
1. Connect power cord to a properly grounded three (3) prong AC110-120V, 60Hz,
single phase receptacle.
2. Motor will start and fan will turn, forcing air out from the heater.
3. Turn the control knob clockwise to OFF position.
4. Turn on propane tank valve slowly, and wait fifteen(15) seconds to clear any gas.
Check the gas connection with a soap or water solution, or if you don't smell gas,
go to next step.
Note: if don’t turn on slowly, overflow profection device (OPD) on propane tank will
stop gas flow, you may hear a click from the OPD closing. If this happens, reset
the OPD by closing propane supply valve and turn on again slowly.
5. Press the ignition switch (43) and a clicking sound will be heard, then push in and turn
the control knob (40) counterclockwise to IGN, this will light the burner.
6. Keep the control knob depressed for 30 seconds or until the thermocouple warms and
allows gas flow.
7. If burner does not stay lit, repeat the lighting procedure.
8. When the burner is lit, release the ignition switch (43), then push in and turn the control
knob (40) counterclockwise to a desired heat setting.
TO START HEATER (MODEL NO.SRCH11033)
Control Knob (40)
Ignition Switch (43)
Warning: Make certain that both ends of the heater are completely unobstructed during ignition
AND operation. Ignite while positioned TO THE SIDE of the heater.
Correct Operation
Wrong Operation