SAFETY CHECK
CHECK FOR LEAKS
Note:
All connection on this heater have been checked for leakage at the factory. Follow these
steps to check regulator/pressure adjustment valve/cylinder connections before operating:
1) The cylinder supply system must be arranged for vapor withdrawal;
2) The cylinder used must include a collar to protect the cylinder valve.
WARNING : ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS
PRODUCT.
1) Make leakage solution by mixing 1 part liquid dish soap and 3 parts water.
2) Spoon or brush several drops (or use squirt bottle) of the solution onto regulator &
pressure adjustment valve connection, regulator & cylinder connection and illustrated
connection joints.
3) Turn on gas cylinder valve. Inspect the connections and look for bubbles.
4) If no bubbles appear, the connection is safe.
5) If bubbles appear, there is leakage. Loosen and re-tighten this connection. If
connection still leaks, please call customer service: 1-866-814-0585.
brush
Note: this installation process applies to both SRCH11011 & SRCH11033