Manual

• Heatmaster/American Gas Log Outdoor Burner/Hearth Kits • IM-126 • Rev. F 01/2019
6
4 4
Installation Instructions
C. Install the Stainless Burner/Pan Assembly
The burner/pan assembly is shipped ready for right-hand
gas connection. See Section 3.B. for left-hand connection.
Remove the existing cap or gas jet assembly from the
gas stub in your replace. Clean the threads using a wire
brush or steel wool. Apply Teon tape or joint compound
to the steel tting and attach the provided brass adapter
to the stub.
Place the burner/pan assembly in the replace. The pan
should be centered both front to back and side to side.
Bend the provided gas connector to facilitate its installation
between the burner and the gas stub.
Attach one end of the gas connector to the brass elbow
or safety pilot tting. Attach the other end to the brass
adapter at the gas tube.
Note: Use caution so Lava rock does not get into the air
mixer on LP models.
Important: Cover the pilot assembly to protect it before
installing the Lava rock.
D.1 Place Lava Rock
Place the desired amount of lava rock on the oor of the
replace.
E. Install the Logs
Fire Risk
Explosion Risk
Personal Injury Risk
Failure to position the parts in accordance
with the diagrams provided with the log
packages or failure to use only parts
approved with this appliance may result in
property damage or personal injury.
WARNING
Install the logs using the installation instructions included
with them.
Light the burner as outlined in the operating section. Allow
the ame pattern to stabilize. If you are satised with the
ame pattern go to the next step. If you want more or less
ame around the front log, turn o󰀨 the gas and move the
grate backward or forward.
Once you are satised, turn on the gas and go on to the
next step.
Arrange the top logs as shown in your log set up
instructions. Light the burner as outlined in the operating
instructions and allow the ame to stabilize.
Spread additional lava rock around the outside of the
burner pan on the oor of the replace. If possible, cover
the gas connector with the cinders. DO NOT cover any
part of the pilot assembly.
F. Adjust the Pilot Flame
The pilot ame should be a soft blue color and should sur-
round the last 1/2 in. of the thermocouple tip. The pilot ad-
justment screw is located on pilot valve beside control knob.
Refer to Figure 4.3. If pilot ame must be adjusted, use a
standard slotted screwdriver to turn screw clockwise to re-
duce ame or counterclockwise to increase ame.
Pilot Adjustment Screw
Figure 4.3 Pilot Adjustment Screw
B. Inspect the Venting System
The replace venting system, if equipped with, shall be
designed and constructed to develop a positive ow
adequate to remove ue gases to the outside atmosphere.
See replace installation instructions.
Cleaning
Periodic examination and cleaning of the venting system
of the replace should be done before initial use and at
least annually by a qualied agency.
A. Install the Damper Stop
If the replace is constructed with a ue:
. Open the damper to the fully open position and
secure it open with the stop as shown below.
. If the damper stop does not t your application,
a permanent means that will keep the damper
open.