Manual
• Heatmaster/American Gas Log Outdoor Burner/Hearth Kits • IM-126 • Rev. F 01/2019
4
Do NOT use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
WARNING
Shock Risk
Fire Risk
Use ONLY optional accessories approved
for this appliance.
• Using non-listed accessories voids
warranty.
• Using non-listed accessories may result
in a safety hazard.
• Only Heatmaster/American Gas Log
approved accessories may be used
safely.
WARNING
A. Gas Supply Connection
A 3/8 in. ared tting has been installed on the gas valve
inlet at the factory. Ensure ttings are of the appropriate size
and type on the gas line connection. If the tubing has to be
cut to length be sure to use the proper cutting and aring
tool. Also, be careful not to crimp the tubing while bending. If
the tubing becomes crimped, do not use for installation.
3 3
Appliance Preparation
Note: An individual manual shuto valve (not supplied) is
required when installing this appliance. The manual shuto
valve must be located in an easily accessible area, no more
than 6 feet from the appliance.
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI 223.1.
Installation should be done by a qualied installer approved
and/or licensed as required by the locality. (In the Common-
wealth of Massachusetts installation must be performed by
a licensed plumber or gas tter.)
WARNING
Gas Leak Risk
• Support control when attaching pipe to
prevent bending gas line.
Fire Risk
Explosion Risk
Personal Injury Risk
An explosion could occur if a connection is
made directly to an unregulated propane (LP)
tank.
WARNING
Joint compound ot Teon tape must be used on all threaded
male connections to ensure a tight seal.
D. Components of the Gas Hearth Kit
The Heatmaster/American Gas Log Burner/Hearth Kit con-
sists of the following:
• Burner/Pan Assembly
• Grate Assembly
• Lava Rock
• Damper Stop
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-o valve
and exible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.