Manual

• Heatmaster/American Gas Log Outdoor Burner/Hearth Kits • IM-126 • Rev. F 01/2019
2
Read this manual before installing or operating this appliance.
Please retain this owners manual for future reference.
Congratulations on selecting a Heatmaster/American Gas
Log Outdoor gas log set—an elegant and clean alternative
to burning wood. The Heatmaster/American Gas Log gas
log set you have selected is designed to provide the utmost
in safety, reliability, and e󰀩ciency.
As the owner of this new gas log set, you’ll want to read
and carefully follow all of the instructions contained in this
owner’s manual. Pay special attention to all cautions and
warnings.
This owner’s manual should be retained for future reference.
We suggest you keep it with your other important documents
and product manuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control sys-
tems.
Your new gas log set will give you years of durable use and
trouble-free enjoyment. Welcome to the Heatmaster/Ameri-
can Gas Log family of appliance products!
Congratulations
Homeowner Reference Information
Model Name: Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
We recommend that you record the following pertinent
information about your gas log set:
1 1
Listing and Code Approvals
B. Table 1
A. Appliance Certication
The Heatmaster/American Gas Log Burner/Hearth Kits have
been tested for outdoor use in the U.S. In accordance
with ANSI Z21.97-2017. CSA2.41-2017 Check with your
local building code agency prior to installing this appliance
to ensure compliance with local codes, including the need
for permits and follow-up inspections. In the absence of
local codes, comply with the National Fuel Gas Code,
ANSI Z223.1-Latest Edition in the U.S.; in Canada, the
CAN/CGA B149 Installation Codes. If any assistance is
required during installation, please contact your local dealer
or Technical Services Department at 919.331.0078 or
919.331.0079.
Product
HM2-SS-
24LP
HM2-SS-
24NG
HM2-SS-
30LP
HM2-SS-
30NG
Inlet BTU
Nat.
LP 40,000 40,000 40,500 40,500
Manifold Pressure IN.
WC/ KPa
Nat. 3.5/.018 3.5/.018
LP 11.0 / 0.057 11.0 / 0.057
Max. Inlet Pressure IN.
WC / KPa
Nat. 10./.052 10./.052
LP 13.0 / 0.068 13.0 / 0.068
Min. Inlet Pressure IN.
WC / KPa
Nat. 10./.052 10./.052
LP 11.0 / 0.057 11.0 / 0.057
Or i c e S i z e
In.
Nat.
LP (.48) (.31) (.45) (.32)
Minimum Fireplace
Opening Size
In. / cm
Front 25” 25” 34” 34”
Depth 14” 14” 14” 14”
Height 15” 15” 15” 15”