FIREPLACE PREPARATION
Before fully installing the unit:
Turn OFF the gas supply to the fireplace or firebox.
Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left
unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the
chimney flue damper.
OPTIONAL VENTED APPLICATIONS
Manual and Remote controlled gas logs may be installed as a vented decorative log set in compliance with
ANSI Z21.60 and National Fuel Gas Code, Section 6.6. Since the gas logs are operated with the damper
open, non-combustible material and minimum mantel requirements do not apply.
Before installing the appliance:
Turn OFF the gas supply to the fireplace or firebox.
Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other
obstructions. Have this cleaning performed annually after installation.
Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left
unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the
chimney flue damper.
Install and operate the appliance as directed in this manual.
Damper Stop Installation:
Damper Stop sold separately.
A damper stop must be provided with the unit.
Contact your dealer to obtain one. The damper
stop must be installed as shown in Figure 10 to pre-
vent full closure of the fireplace damper blade and
provide a minimum 29 sq. in. flue opening.
Before installing in a solid fuel burning fireplace, the chimney flue
and firebox must be cleaned of soot, creosote, ashes and loose paint by a
qualified chimney cleaner.
This appliance is for installation only in a solid fuel burning fireplace
(masonry of manufactured fireplace) with a working flue and
constructed of non-combustible material.
Figure 10.
Damper stop installation.
Damper Stop sold separately.