Manual
FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
A. This appliance is equipped with an electronic ignition pilot. This pilot lights itself with either the
manual on/off button or with the remote control transmitter that is provided.
B. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
♦ Do not try to light any appliance.
♦ Do not touch any electrical switch; do not use any phone in your building.
♦ Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instruc-
tions.
♦ If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in the switch buttons. Never use tools. If the buttons will not push in by
hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result
in fire or explosion.
D. Do not use room heater if any part has been under water. Immediately call a qualified service techni-
cian to inspect the room heater and to replace any part of the control system and any gas control
which has been under water.
TO TURN OFF GAS TO APPLIANCE
1. Press the off button on the remote control. If not using a remote control press the on/off rocker switch.
2. Close the appliance shutoff valve.
LIGHTING INSTRUCTIONS
1) STOP! Read safety information previously listed above.
(2) Insure main gas supply is turner on to the appliance.
(3) Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow “B” in the safety information above. If you do not smell gas, go on to the next step.
(4) To start pilot ignition manually, move ON/OFF switch to on. After a few seconds pilot will spark and ignite
pilot and burner flame to high flame position.
(5) For low flame move HI/LO switch to on and flame will move to low position. To return to high flame move
HI/LO switch back to HI and flame will go back to high position.
(6) To turn burner off move ON/OFF switch to off position.
(7) Remote will operate system manually or thermostatically. To light manually press ON button once. Press H/L
button to cycle between Hi, Med, and Low settings. Press OFF button to cut system off.
(8) To operate system thermostatically, press MODE button and the word Room will appear on the screen. Press
Set button to achieve desired operational temperature.
(9) If you start system remotely with ON button while in thermostat mode, remote reverts back to manual func-
tion and you will have to reset mode button to return to thermostatic function.
(10) Pressing the Continuous Pilot button with unit off will light pilot only and pilot will continue to burn until
system gets command for main burner operation. Pressing Continuous Pilot button again will cut pilot off and
return system back to pilot spark ignition function. Note: Wait 5 minutes before trying to relight pilot with spark
ignitor or remove battery power for 30 seconds.
ECO Electronic Ignition