D. Troubleshooting
With proper installation and maintenance, your new decorative gas appliance should provide years of trouble-free service.
If you do experience a problem, refer to the troubleshooting guide below. This guide will assist you or a qualied service
technician in the diagnosis of problems and the corrective action to be taken.
Symptoms Possible Causes Corrective Action
1. A match will not light the
pilot.
A. Main gas shuto valve is
closed
1. Make sure that the shuto valve located on the
incoming gas line is open.
B. There is air in the gas line. 1. Light a match. Turn the valve knob to the “PILOT”
position and depress. Keep the match near the pilot
burner until it lights.
C. The valve knob is in the
“OFF” position.
1. Turn the valve knob to the “PILOT” position and
depress. Keep the match near the pilot burner until it
lights.
D. The pilot orice is plugged,
not allowing gas to ow.
1. This repair requires tools and some degree of
experience. Call a qualied service technician.
E. There is no gas supply to
the replace.
1. Check the plumbing to ensure the replace has been
hooked up the gas supply line.
2. The propane tank is empty.
2. The pilot lights, but
will not stay lit after
carefully following lighting
instructions.
A. The thermocouple is too
tight or too loose.
1. The thermocouple must be attached to the valve
nger-tight plus a 1/8 turn with a wrench.
B. There is a weak pilot
ame.
1. The pilot ame must engulf the thermocouple.
Clean and/or adjust the pilot for maximum ame
impingement on the thermocouple.
C. Defective thermocouple 1. Check the thermocouple with a millivolt meter as
follows: Disconnect the thermocouple from the valve
and connect the red lead of the meter to the silver end
of the thermocouple. Connect the black lead of the
meter to the copper tubing of the thermocouple. Light
the pilot and keep the knob depressed while taking
readings. The meter readings should be greater than
14 mV. If not, replace the thermocouple.
3. The pilot is on, but there is
no gas to the main burner;
the valve knob is on.
A. A blockage is preventing
gas ow.
1. Inspect the burner orice for obstruction. Call a
qualied service technician.
B. Defective valve. 1. Replace the gas valve. Call a qualied service
technician.