B. Securing Stove Pipe/Liner to Flue Collar
1.Thereare4pre-drilledholesintheuecollar90degrees
apart.Attachtheuecollartothestovepipe/liner.Ifthe
sealisquestionableusestovemasticFigure 40.1.
2.Attachgaskettobottomsideofuecollarwithathincoat
ofsilicone.
Flue Collar
Stove Pipe/Liner
Gasket
Figure 40.1
Figure 40.2
Figure 40.3
Figure 40.4
C. Optional Offset Adapter Installation
Insome installationstheuecollarand stovepipe/linerdo
notalwaysalignproperly.Thissituationmayberemedied
byusingtheoptionaloffsetadapter.SeeApplianceDimen-
sions page for the amount of distance this accessory can
telescopebetweentheuecollarandstovepipe/liner.
1.Removethecast ironuecollarfromtheapplianceand
ipitupsidedown.Usingthelarger#7drillbitsupplied,
drillthroughall8countersunklocations.Figure 40.2.
2.Slidethegasketoverthetheuecollarandattachittothe
offsetadapterusing the 8-32 athead screws provided.
Figure 40.3.
3.Adjusttheoffsetadaptertodesireddistance.Drillholes
throughthelowerchamberasshowninFigure 40.4using
thesmalldrillbit#26provided.
4.Cutthegaskettotheproperlengthandslideinbetween
the upper and lower chambers centered on the screw
holes.Attachtheupperandlowerchamberswithscrews
provided.Figure 40.5.
5.Repeattheprocessonthebottomside.
Cast Iron Flue Located on Appliance
Drill through all 8 countersunk
locations
Once distance is established, drill holes
and secure both chambers together.
Figure 40.5