The following modications of factory-built replaces are
permissible:
• The replace must not be altered. Cutting any sheet
metalpartsofthereplaceinwhichthereplaceinsertis
tobeinstalledisprohibitedperANSIZ21.88exceptthat
thedampermayberemovedtoaccommodateadirect-
connectstarterpipeorchimneyliner,
• External trim pieces which do not affectthe operation
ofthereplacemayberemovedprovidingtheycanbe
stored on or within the replace for reassembly if the
insertisremoved.
• The permanent metal warning label provided in the
component pack must be attached to the back of the
replace,withscrewsornails,statingthatthereplace
may have been altered to accommodate the insert,
andmustbereturnedtooriginalconditionforuseasa
conventionalreplace.Figure 38.2.
• Manufacturerdesigned adjustable support kit can be
orderedfromyourdealer.
• Finalapprovalofthisinstallationtypeiscontingentupon
theauthorityhavingjurisdiction.
Damper SmokeShelforBafe
EmberCatches FireGrate
ViewingScreen/Curtain Doors
Thefollowingpartsmayberemoved:
LINER CONNECTOR
FLUE
GAS
DIRECTION
CRIMPED
END
TOWARDS
STOVE
Figure 38.1
H. Altering the Fireplace
G. Securing Chimney Components
All joints should be secured with 3 sheet metal screws or
rivetsperpipemanufacturersinstructions.Thesectionsmust
beattachedtotheinsertandtoeachotherwiththecrimped
(male)endpointingtowardtheinsert.Figure 38.1.
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
with 1/8 in. holes on both sides.
Black letters
Figure 38.2
WARNING! Risk of Asphyxiation!
• DONOTCONNECTTHISAPPLIANCETO
ACHIMNEYFLUESERVICINGANOTHER
APPLIANCEORTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Thismayallowuegasestoenterthehouse.
I. Factory-Built Sold Fuel Fireplace
Apermitmayberequiredforinstallations,nalapprovalis
contingentoftheauthorityhavinglocaljurisdiction.Consult
insurancecarrier,localbuilding,reofcialsorauthorities
having jurisdiction about restrictions, installation inspec-
tion,andpermits.
Inspecttheexistingreplaceandchimneyforanydamage
orawssuchasburnouts,metalorrefectorywarping.
Inspection to a minimum of NFPA211Level II is recom-
mended. All repairs must be made prior to installing an
insert. The replace must be structurally sound and be
abletosupporttheweightofthesolid-fuelinsert
Thefactory-builtchimneymustbelistedperUL127orULC
610-M87forallinstallations.Installthermalprotectionper
thisappliancelistingrequirements.
A full height 6 inch diameter stainless steel full height
listed chimney liner must be installed meeting type HT
(2100°F) requirements per UL 1777 (USA) or ULC S635
with “0” clearance to masonry (Canada). The full liner
must be attached to the insert ue collar and to the top
of the existing chimney.
Theuelinertopsupportattachmentmustnotreducethe
air ow for the existing air-cooled chimney system. Re-
installoriginalfactory-builtchimneycaponly.(SeeSec-
tionF.,PrefabricatedMetalChimney)
Topreventroomairpassagetothechimneycavityofthe
replace,sealeitherthedamperareaaroundthechimney
linerortheinsertsurround.Circulatingairchamber(i.e.in
asteel replace liner or metalhearth circulator) may not
beblocked. The air owwithinandaroundthe replace
shallnotbealtered,blockedbytheinstallationoftheinsert.
(i.e.no louvers orcoolingairinletor outletportsmaybe
blockedbytheinsertortheinsertsurround.
See“H.AlteringtheFireplace”formodicationsallowedfor
factory-builtreplaces.