H. Burn Rate Air Control
• The air supply enters at the upper front of the rebox,
nearthetopoftheglassdoor.
• Thispreheatedairsuppliesthenecessaryfreshoxygen
tomixwith the unburnedgases, helping to createsec-
ond,thirdandfourthcombustions
• ThisairisregulatedbytheBurnRateAirControl.
• TherearefoursettingsHigh,Medium-High,Medium-Low
andLow.
• WhenthecontrolisraisedallthewayupitisontheHigh
settingand when pushed all the down it is on the Low
setting.Figure 10.1.
I. Burn Rates and Operating Efciency
For maximum operating efciency
1. Followtheinstructionsbelowforeachburnrateforthe
BurnRateAirControl.Figure 10.1.
2. Burndry,well-seasonedwood.
Burn Rates
1. Starting a Fire
• OpentheBurnRateAirControlbyraisingitalltheway
tothetopfortheHighsetting.

• Theblowertendstocooltheappliance.Leavetheblower
offuntiltheburniswellestablished,i.e.,30minutes.
• Afterloadingtheappliancewith wood andstartingthe
re,settheBurnRateAirControlstothedesiredsetting
byfollowingtheburnrateinstructionsbelow.
2. High Burn Rate - Maximum Heat* - 30,000+ BTU/hr
•
Raise the Burn Rate Air Control all the way up until it
stops(topmarker)toafullyopenposition.
•
Besureandmonitortherecloselywhileinthissettingto
avoidoverringyourstove.
3.
Medium-High Burn Rate* - 15,000 to 30,000 BTU/hr
• Raise the Burn Rate Air Control to the Medium High
marker.
Blowermayremainon.
4.
Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
• RaisetheBurnRateAirControltotheMediummarker.
Leave the blower off until the burn is well established,
i.e.,30minutes.
5. Low Burn Rate* - Below 10,000 BTU/hr
• LeavetheBurnRateAirControlatthebottommarker.
Leave the blower off until the burn is well established,
i.e.,30minutes.
*NOTE:
Theseareapproximatesettings,andwillvarywith
type of wood or chimney draft. Due to altitude and other
environmentalcircumstances,thisoperationalinformationis
aguidelineonly.
Figure 10.1 - Burn Rate Air Control
-HIGH
-MEDIUM HIGH
-MEDIUM
-LOW