Indoor Fireplace User Manual

33Heatilator • RAVE4013I-C • 2293-900 Rev. C • 8/12
Clearances to Combustibles:
Refer to Section 5 for clearances to the appliance, man-
tel, mantel legs and wall projection.
Refer to Section 8 for pipe clearances to combustibles.
Termination Cap
For installation of termination cap see minimum vent
heights for various pitched roofs. See Section 6 of appli-
ance owners manual.
Flue Damper
Fully lock the solid fuel replace’s ue damper in the open
position, OR completely remove it.
Venting Components
The LINK-DV30B is approved for use with the coaxial/co-
linear venting application. The LINK-DV30B kit includes:
Two 30 feet sections of exible vent pipe (3 inches Ø).
One section is used to draw combustion air and the other
section is used to expel exhaust gases.
• One vertical termination cap.
WARNING! Risk of Fire! Coaxial to colinear venting
con guration may only be used in existing non-combus-
tible chimney. Installation in any other venting application
could cause re.
Prior to installing the gas appliance:
Have the chimney and adjacent structure inspected
and cleaned by quali ed professionals. Hearth & Home
Technologies recommends that NFI or CSIA certi ed pro-
fessionals, or technicians under the direction of certi ed
professionals, conduct a minimum of a NFPA 211 Level
2 inspection of the chimney.
Replace component parts of the chimney and replace
as speci ed by the professionals.
Ensure all joints are properly engaged and the chimney
is properly secured.
EXHAUST VENT PIP
E
INLET AIR VENT PIPE
Figure 7.14 Coaxial/Colinear Appliance Adapter (DV-46DVA-GCL)
Coaxial to Colinear Venting
The coaxial to colinear adapter (DV-46DVA-GCL) is ap-
proved for installations into solid fuel masonry or factory
built replaces that have been installed in accordance
with the National, Provincial, State and local building
codes. The DV-46DVA-GCL must be recessed into exist-
ing masonry replace. See Table 1 and Figure 7.15.
OUTSIDE FACE OF
FIREPLACE
TOP OF FIREPLACE
OPENING
SHADED AREA DEFINED AS
“INSIDE EXISTING MASONRY FIREPLACE”
3 IN. MIN.
5 IN. MIN.
EXHAUST VENT PIPE
Figure 7.15 Existing Fireplace DV-46DVA-GCL Clearance
Requirements
Table 1
CLEARANCE TO COMBUSTIBLES REQUIREMENTS
DV-46DVA-GCL 3 IN.
Exhaust Vent Pipe 5 IN.
CAUTION! DO NOT use any ue restrictor when vent-
ing with the DV-46DVA-GCL adapter and LINK-DV30B
kit. This may result in poor ame appearance, sooting,
pilot malfunction, or overheating.